Dingbo's set type DB-32GF pairs a DCEC Cummins 4BT3.9-G1 engine with a 40 kVA alternator, giving a continuous electrical output of 32 kW at the standard 0.8 power factor, 50 Hz, 400/230 V three-phase. It sits in the smaller end of Dingbo's Cummins-powered range, between the 25 kVA and 62.5 kVA models, and is typically specified for shops, telecom cabins, small workshops and single-building backup where a 32 kW running load is a reasonable fit.

The Dingbo DB-32GF 40 kVA Cummins Diesel Generator is powered by a DCEC Cummins 4BT3.9-G1 diesel engine and delivers a published electrical output of 32kW/40kVA at 50Hz, 400/230V and 0.8 power factor. This four-cylinder, turbocharged diesel generator is available in open-type and soundproof configurations for commercial backup power, small industrial equipment and site power applications.


DB-32GF 40 kVA Generator Key Specifications

ParameterPublished Specification
Generator Set ModelDB-32GF
Rated Generator Output32kW / 40kVA
Engine ManufacturerDCEC Cummins
Engine Model4BT3.9-G1
Engine Prime Power36kW (engine mechanical rating)
Engine Standby Power40kW (engine mechanical rating)
Rated Frequency50Hz
Rated Speed1500rpm
Rated Voltage400/230V
Rated Current57.6A
Power Factor0.8 Lagging
Phase / ConnectionThree-phase, four-wire, Y connection
Engine Configuration4-cylinder inline, four-stroke, turbocharged
Displacement3.9L
Starting System24V DC
Cooling SystemWater-cooled
Standard ControlDingbo Standard Control Panel
Available Generator TypesOpen Type / Soundproof Type

Generator Output vs. Cummins Engine Power

The DB-32GF's published generator output is 32kW/40kVA. The Cummins 4BT3.9-G1 engine has separate mechanical ratings of 36kW prime and 40kW standby. These engine ratings must not be interpreted as the complete generator set's electrical standby output.

For standby applications, request confirmation of the complete generator set's applicable emergency standby rating. Engine reserve power and alternator short-term overload capability do not independently determine whether a generator can start a large electric motor. Motor starting performance must be evaluated using the starting current, starting method, allowable voltage dip and alternator characteristics.

Is a 40 kVA Cummins Generator Suitable for Your Load?

A 40kVA generator rated at 0.8 power factor provides 32kW of published electrical output. Before ordering, check the connected running load, starting demand and operating duty rather than selecting solely by the total equipment nameplate capacity.

Selection FactorWhat to CheckRecommendation
Running LoadTotal simultaneous kW and kVA demandConfirm that the operating load remains within the applicable generator rating.
Prime or Standby DutyRegular power generation or emergency backup operationSpecify the intended duty so the correct genset PRP or ESP rating can be confirmed.
Motor StartingStarting current, starting method and permitted voltage dipProvide motor nameplate data for pumps, compressors, fans and other high-inrush equipment.
Voltage and FrequencyRequired voltage, 50Hz/60Hz and phaseConfirm compatibility with the electrical equipment and destination market.
Operating EnvironmentAltitude, ambient temperature, ventilation and installation locationCheck cooling conditions and potential generator derating.
Future ExpansionPlanned additional equipment and future load growthConsider a higher-capacity model if the expected demand approaches the generator's usable rating.

When Should You Choose a Larger Generator?

If the calculated running load, required motor starting capacity or future expansion exceeds the DB-32GF's suitable operating range, a higher-capacity generator should be considered. Dingbo also offers a 50kW / 62.5kVA Cummins QSB3.9-G35 Diesel Generator. The two models use different engine configurations, so their electrical performance and operating costs should be compared using the corresponding technical datasheets.

Open Type vs. Soundproof 40 kVA Cummins Generator

Both configurations are available for the DB-32GF. The main purchasing differences are installation space, weather protection, noise-control requirements, transport weight and enclosure cost. The dimensions below are Dingbo's published reference specifications for this model.

ComparisonOpen TypeSoundproof Type
Generator ModelDB-32GFDB-32GF
Published Output32kW / 40kVA32kW / 40kVA
Dimensions (L × W × H)1600 × 750 × 1200mm1860 × 760 × 1300mm
Weight700kg900kg
Acoustic EnclosureNoYes
Weather ProtectionRequires suitable site protectionDepends on the specified enclosure design
Installation RequirementsGenerator room or protected equipment locationSuitable indoor or outdoor installation with adequate ventilation
Noise PerformanceDepends on installation conditionsModel-specific noise performance to be confirmed

The soundproof unit has a larger enclosure and higher published weight. For projects with a specified noise limit, provide the required dB(A) level, measurement distance and operating conditions. Dingbo can evaluate the appropriate acoustic enclosure rather than applying an unverified universal noise value to all configurations.

Fuel Consumption and Operating Cost Reference

The Cummins 4BT3.9-G1 engine data published for DB-32GF includes fuel consumption at different prime-load conditions. These figures can support preliminary fuel budgeting, while actual consumption depends on the operating load, environmental conditions and final configuration.

Operating ParameterPublished ValuePurchasing Consideration
Fuel Consumption at 100% Prime Load10L/hUse as a published reference for full-load fuel budgeting.
Fuel Consumption at 50% Prime Load5.9L/hUse when estimating consumption at partial load.
Starting Voltage24V DCConfirm battery and charging arrangements.
Daily Fuel TankOptionalSelect capacity based on required runtime and fuel consumption.
Fuel Level SensorOptionalUseful for monitoring unattended or longer-duration operation.
Water SeparatorOptionalSpecify according to fuel system and maintenance requirements.

For extended standby operation, provide your required operating hours and expected load level. The fuel tank can then be selected according to usable tank volume and the applicable fuel consumption data. No fixed eight-hour runtime should be assumed without confirming the installed tank capacity.



Send your load schedule, largest motor and its starting method, standby or prime duty, voltage/frequency, site altitude, enclosure preference, required runtime and destination country. We'll confirm the configuration and reply with an itemized quotation.

Request a Quotation


Standard, Optional and Custom Specifications

Dingbo offers the DB-32GF in its published 50Hz, 400/230V configuration, together with optional and customized electrical, enclosure and control arrangements. The options below can be specified during quotation. Each configuration must be matched to the appropriate engine, alternator, installation environment and operating duty.

ParameterStandard / Published SpecificationOptional ConfigurationCustom Scope
Generator Output32kW / 40kVAAlternative engine or genset selectionCapacity matched to actual load; another engine or rating requires a separate configuration
Frequency50Hz60HzCompatible engine speed, alternator and output rating selected for the required frequency
Voltage400/230V380/220V, 415/240V, 440/254VOther compatible voltage configurations according to the project electrical specification
Electrical PhaseThree-phase, four-wireSingle-phase arrangement subject to suitable equipment selectionSpecial electrical arrangements based on load and alternator compatibility
Alternator BrandCompatible single-bearing alternator; final brand per orderLeroy-Somer, Stamford, Siemens, Marathon, ENGGA, KEPUSpecified compatible alternator brand and model
Alternator ExcitationAccording to the selected alternator modelPMG and compatible excitation optionsSelected according to load characteristics and electrical performance requirements
Control PanelDingbo Standard Control PanelAutomatic, remote control and parallel control panelsSpecified controller functions, communication interfaces and operating sequence
Automatic TransferNot included as a universal standard componentATSATS selection according to rated current, system voltage and transfer logic
EnclosureOpen or soundproof configurations availableRainproof, trailer-mounted and alternative soundproof designsEnclosure dimensions, ventilation, maintenance access and acoustic design
Enclosure MaterialStandard material grade not uniformly specifiedMetal enclosure constructionCustomer-specified steel grade, panel thickness and structural arrangement
Surface TreatmentStandard coating specification not uniformly publishedPowder coating and protective paint finishesSpecified finish, color, coating thickness and corrosion-protection requirements
Fuel TankStandard tank capacity to be confirmedDaily fuel tank and fuel level sensorFuel capacity selected according to the required operating duration and installation space
Auxiliary EquipmentStandard starting, cooling and protection componentsBattery charger, engine heater, alternator heater and water separatorCompatible auxiliary components according to operating conditions
ParallelingNot standardParallel control panel and associated equipmentSynchronization and load-sharing arrangement with compatible generator units

Custom configuration limits: The original 4BT3.9-G1 engine ratings, 50Hz output and published equipment dimensions cannot automatically be applied to a different voltage, frequency or generator arrangement. Custom material grades, enclosure thickness, protective coatings and sound performance must be defined in the purchase specification. The final design and technical datasheet will identify the agreed configuration and applicable performance requirements.

Automatic Control, ATS and Parallel Operation

The DB-32GF can be equipped with different control systems depending on whether the generator is operated locally, starts automatically during a mains failure or forms part of a more complex electrical system.

Control OptionAvailable FunctionsWhen to Specify
Standard Control PanelGenerator monitoring, operating information, alarms and local control functionsSites with a designated operator or straightforward generator operation
Automatic Control PanelAutomatic starting and stopping using compatible control modulesUnattended standby applications
Remote MonitoringRemote operating information and communication functions depending on controller modelSites requiring equipment monitoring from another location
Automatic Transfer SwitchPower source transfer with compatible generator control arrangementsFacilities requiring automatic transfer between mains and generator power
Parallel Control PanelSynchronization and load-sharing functions with compatible equipmentMultiple-generator projects and planned capacity expansion

For automatic backup applications, Dingbo offers generator automatic transfer switch solutions. Confirm the ATS current rating, electrical connection and required control sequence before ordering.

Custom Enclosure Material and Surface Treatment

For outdoor, industrial or project-specific installations, Dingbo can provide customized generator enclosures based on structural, environmental and appearance requirements. Buyers can specify the enclosure material, protective coating, dimensions and maintenance access during quotation.

Custom ItemAvailable ScopeRequired Project Information
Metal EnclosureSteel enclosure construction with project-specific material and thicknessRequired material grade, thickness and structural requirements
Protective CoatingPowder coating or suitable protective paint systemOperating environment, coating specification and corrosion protection requirements
Finish and ColorSpecified industrial finish and colorColor reference and visual requirements
Acoustic TreatmentCustomized sound-attenuating enclosureTarget sound level, measurement distance and installation conditions
Enclosure DimensionsProject-specific layout and access arrangementAvailable installation space and maintenance clearance
Trailer ConfigurationMobile generator mounting arrangementOperating location, total equipment weight and transport requirements

For projects where sound control is the primary purchasing requirement rather than the specific Cummins engine model, see Dingbo's 32kW / 40kVA Silent Diesel Generator. That product covers a broader choice of engine brands, while the DB-32GF focuses on the Cummins 4BT3.9-G1 configuration.

Documents and Commercial Details to Confirm Before Ordering

The final quotation should identify the engine, alternator, rated output, electrical configuration, control system, enclosure, accessories and delivery conditions. Technical documents and compliance requirements should be agreed before order confirmation, particularly for projects importing generators into regulated markets.

Purchasing ItemWhat to Confirm
Final Technical DatasheetDB-32GF configuration, complete genset power rating, engine model, alternator and all electrical parameters
Prime / Standby RatingThe applicable complete generator set PRP and ESP ratings, rather than engine power alone
Certification DocumentsAvailable documents applicable to the selected generator model and destination market
Factory InspectionAvailable inspection or test records and any additional acceptance requirements agreed before ordering
Dimensions and WeightConfirmed drawings and shipping data for the final enclosure and accessories
MOQ and QuantityRequired order quantity and applicable commercial terms
Production and DeliveryConfirmed production schedule, shipping destination and delivery terms
Warranty and SupportApplicable warranty conditions, technical support and service arrangements

Dingbo publishes company-level certification and factory testing information. However, certificate applicability and any special inspection procedure must be confirmed for the individual generator configuration. A specific emissions approval, noise test result or factory load-test sequence should not be assumed without the relevant model documentation.

40 kVA Cummins Diesel Generator Purchasing FAQs

1. Is the DB-32GF a 32kW or 40kW generator?

The complete generator set has a published electrical output of 32kW/40kVA at 0.8 power factor. The Cummins 4BT3.9-G1 engine has separate mechanical prime and standby ratings of 36kW and 40kW. These engine figures are not the complete generator set's electrical output ratings.

2. What is the standby output of this 40kVA Cummins generator?

The published generator set output is 32kW/40kVA. Its engine standby power is stated as 40kW, but a separate complete generator set ESP rating must be confirmed in the final technical datasheet. Buyers should specify whether the generator is intended for prime or emergency standby service before ordering.

3. Can this generator start a pump, compressor or other electric motor?

Motor starting suitability depends on starting current, starting method, permitted voltage dip, alternator excitation and engine response. Provide the motor power, starting arrangement and other loads operating simultaneously. Dingbo can review whether the DB-32GF is suitable or whether a larger generator or different starting system is required.

4. Can I order the DB-32GF in 60Hz or a different voltage?

Yes, compatible alternative electrical configurations can be specified. Available options include 60Hz and voltage arrangements such as 380/220V, 415/240V and 440/254V. The final engine speed, alternator selection and electrical output must be confirmed for the requested configuration. The published 50Hz data should not be assumed to remain unchanged.

5. Can I choose the alternator brand?

Yes. Dingbo lists Leroy-Somer, Stamford, Siemens, Marathon, ENGGA and KEPU among its available alternator options. Confirm your preferred brand and model during quotation. Different alternators may have different electrical characteristics, dimensions, excitation systems and prices.

6. What is the difference between the open and soundproof versions?

The published open version measures 1600 × 750 × 1200mm and weighs approximately 700kg. The soundproof version measures 1860 × 760 × 1300mm and weighs approximately 900kg. The soundproof configuration adds an enclosure, but its final noise performance should be confirmed against the required acoustic specifications and measurement conditions.

7. Can I request a custom steel enclosure and powder-coated finish?

Yes. Custom metal enclosure materials, panel thicknesses, protective coatings, colors and structural layouts can be specified. Provide the required material, coating performance, site exposure conditions and any drawings. Final dimensions and coating details will be confirmed during technical review.

8. Can the fuel tank support eight hours of operation?

An extended-runtime fuel tank can be configured according to the required operating hours and expected load. The published engine fuel consumption is 10L/h at 100% prime load and 5.9L/h at 50% prime load. The final tank capacity and usable runtime must account for the actual load, usable fuel volume and operating conditions. An eight-hour runtime is not a fixed standard specification without a confirmed tank arrangement.

9. Can I order the generator with ATS and remote monitoring?

Yes. Automatic control, ATS, remote operation and paralleling options are available. Provide the electrical system information and required control functions so compatible equipment can be selected. These options are not automatically included in every standard DB-32GF configuration.

10. What is the MOQ and delivery time for this model?

MOQ and delivery time depend on quantity, component selection and customization requirements. Provide your required quantity, destination country, preferred configuration and target delivery date. The applicable production schedule and commercial terms will be confirmed in the quotation.

11. Can Dingbo provide certificates and factory test documents?

Buyers can request available technical documentation, applicable certificate details and factory inspection information for the selected generator. Required destination-country compliance documents and special acceptance tests should be specified before order confirmation. The availability and scope of documents must be verified for the exact configuration being supplied.

Request a Quote for the 40 kVA Cummins Diesel Generator

Looking for a 32kW/40kVA Cummins generator powered by the 4BT3.9-G1 engine? Dingbo Power can help you confirm the required power rating, select a compatible alternator and control system, and choose between open, soundproof or customized generator configurations.

To receive an accurate technical proposal and quotation, provide the following purchasing information:

RFQ InformationDetails Required
ProductDB-32GF, Cummins 4BT3.9-G1, 32kW/40kVA
Operating DutyPrime or standby, expected operating hours and load profile
Electrical RequirementsVoltage, 50Hz/60Hz, phase and any special load requirements
Motor StartingLargest motor size, starting method and simultaneous loads
EnclosureOpen, soundproof, rainproof, trailer or custom enclosure requirements
Alternator and ControllerPreferred brands, ATS, remote monitoring and other control options
Fuel and AccessoriesRequired operating duration, fuel tank, heaters and charging equipment
Site ConditionsAmbient temperature, altitude, available space and noise limits
Order DetailsQuantity, destination country and requested delivery date

Contact Dingbo Power for your DB-32GF quotation. Use the Inquire Now option on this 40 kVA Cummins Diesel Generator product page and send your requirements. Our team can review the requested configuration and provide model-specific technical information and commercial terms for your purchasing decision.

40 kva cummins diesel generator specifications

Diesel Engine Data

Manufacturer:

Cummins

Model:

4BT3.9-G1

Prime Power:36KW

Standby Power:

40KW 

Rated Speed:

1500(r/min)

Cycle:

4 stroke

Cylinder Arrangement:

4 in line

Displacement:

3.9L

Bore and Stroke:

102*120(mm) 

Compression Ratio:

17.3:1

Governor Type:

BYC A/RSV Mechanical

Start battery voltage:

24V DC

Air Intake System

Air Intake System:

Turbocharged

Max Intake Restriction:

6kPa

Burning Capacity:

1.98m3/min

Air Flow:

136m3/min



Exhaust System

Exhaust Gas Flow:

4.27m3/min

Exhaust Temperature:

410℃ 

Max Back Pressure:

10kPa



Fuel System

Fuel System:

BYC A/RSV Mechanical, direct injection

100%( Prime Power) Load:

10L/h

50%( Prime Power) Load:

5.9



Oil System

Total Oil Capacity:

10.9L

Oil Consumption:

≤0.4g/kwh

Engine Oil Tank Capacity:

8.5-9.5L

Oil Pressure at Rated RPM:

345kPa

Cooling System

Cooling Way:

Water-cooled
Total Engine Coolant Capacity:7.2L
Thermostat:82-95℃ 
Max Water Temperature:104℃ 

Alternator Data

Manufacturer:


LEROY SOMER/ 
STAMFORD/ 
SIEMENS/ 
MARATHON/ 
ENGGA / 
KEPU
Excitation Mode:Time harmonic wave excitation
Number of phase and Access Act:3-phase 4-wire
Connecting Type:"Y" type connecting
Alternator Capacity:40KVA
Alternator Efficiencies:95%
Overload:(PRP)110% load can run 1h
Protection Level:IP22-IP23
Insulation Class, Temperature Rise:H/H
Telephone Influence Factor (TIF):<50
THF:<2%
Voltage Regulation, Steady State:≤±1%
Air Cooling Flow:2.69m3/s
Altitude:≤1000m

Genset Electrical Performance

Voltage Regulation:

≥±5%
Voltage Regulation, Stead State:≤±1%
Sudden Voltage Warp (100% Sudden Reduce):≤+25%
Sudden Voltage Warp (Sudden Increase):≤-20%
Voltage Stable Time (100% Sudden Reduce):≤6S
Voltage Stable Time (Sudden Increase):≤6S
Frequency Regulation, Stead State:≤5%
Frequency Waving:≤1.5%
Sudden Frequency Warp (100% SuddenReduce):≤+12%
Sudden Frequency Warp (Sudden Increase):≤-10%
FrequencyRecoveryTime(100%SuddenReduce):≤5S
FrequencyRecoveryTime(Sudden Increase):≤5S
Options
EngineAlternator
Heater 2KW & 4KWAnti Condensation Heater
Battery Charger 3.5A & 7APermanent Magnet Generator(PMG)
Water SeparatorDrop CT(For Paralleling)
Daily Fuel Tank
Fuel Level Sensor
Control SystemOthers
Remote Control PanelRainproof Type
Auto Transfer Switch (ATS)Soundproof Type
Paralleling SystemTrailer Type
Open Type
Overall SizeWeight
1600(mm)*750(mm)*1200(mm)700(kg)
Cummins open type image.jpg
Soundproof Type
Overall SizeWeight
1860(mm)*760(mm)*1300(mm)900(kg)
Cummins 1200 GF Image.png


Standard Control Panel
Cummins 24GFDingbo Standard Control Panel uses micro processing technique integrating digital, intelligent and network techniques which can carry out functions including auto start/stop, data measure, alarming. The controller uses LCD display, optional Chinese and English display interface with operation easy and reliable. It can be widely used in all types of generator automatic control system for compact structure, advanced circuits, simple connections and high reliability


Auto Module Control Panel
Cummins 24GFAuto Module Control Panel is the configuration for nobody on duty controlling generators. This kind of panel adopts auto module control system, with large LCD display to show the menu. Features: 6110 can receive remote output signal from ATS and realize auto start and stop of generators. 6310 can realize all functions of 6110, add RS232 interface which can communicate with PC to realize remote operation. 6410 Auto Mains Failure controller, can realize all functions of 6310, furthermore can detect  ATS and control directly. 
Auto Parallel Control Panel
Cummins 24GFThis new automatic parallel system adopts intelligent modules, inserted and folded installed, no need the peripheral relay and logic circuit. The main switch adopts electronic breaker or frame breaker, combined together with the generator, which is very reliable. One generator, one panel. The panel can be used both for singly and parallel. It is only need to parallel generator with such panel when the capability needs to be enlarged in the future.


45KW 56KVA Cummins Diesel Generator Set
145kW Cummins QSB5.9-G33 Diesel Generator Set
90kW 112.5kVA Cummins QSB5.9-G2 Diesel Generator

Contact Us

  • Add.: No. 10 Kechuang Road, High tech Zone, Nanning, Guangxi, China
  • Tel.: +86 771 5805 269
  • Fax: +86 771 5805 259
  • Cellphone: +86 134 8102 4441
                    +86 138 7819 8542
  • E-mail: [email protected]
Follow Us

Copyright © Guangxi Dingbo Generator Set Manufacturing Co., Ltd. All Rights Reserved | Sitemap

Update cookies preferences

generator set:

Emergency vs Standby Generator: What’s The Difference? Commercial Generators Trailer Mounted Water Pumps for Sale
Contact Us