In March 2025, a valued client from Madagascar placed an order for a 88kW diesel generator and a 160kW diesel generator with Dingbo Power. The generator sets have been completed as scheduled and are ready to export. They are engineered with premium components to ensure durability and performance. Each unit integrates a high-efficiency Shangchai diesel engine, paired with a Shanghai Stamford alternator renowned for its stable output and longevity.

 

Main technical data of 88kW diesel generator set


Manufacturer:Guangxi Dingbo Generator Set Manufacturing Co.,Ltd
Genset modelDB-88GF
TypeSilent Type
Prime power:110KVA/88KW
Standby power:121KVA/97KW
Rated current:167A
Rated voltage:380V
Rated speed1500rpm
Rated frequency50Hz
Power factor:0.8lag
Phase:3 phase 4 wire
Noise level75dBA at 7 meters
Fuel Tank8 hours’ Supply
Dimension (L x W x H):2700*1100*1700 mm
Gross weight:1600kg


Two Shangchai Silent Diesel Generators Will Be Exported to Madagascar


Diesel engine specifications


Manufacturer:Shanghai New Power Aotomotive Technology Company Limited
Engine modelSC4H140D2
Prime power:95kW
Standby power:105KW
Frequency:50Hz
Speed:1500rpm
Cylinders no. & Type:4 cylinders, Inline, 4 stroke, diesel engine, water-cooled
Aspiration:Turbo charged & Air-to-air intercooled
Displacement:4.3L
GovernorElectronic speed governor
Bore x Stroke(mm):105*124mm
Compression Ratio:16:1
Start mode:Electric start
Starter motor voltage:24V DC
Type Injection System:direct injection
Oil Pan Capacity - Low / High11L-13L
Coolant Capacity - Engine Only6.8L
Fuel consumption-standby power100%: 25.9L/h
Fuel consumption-prime power

100%: 23L/h

75%: 17.1L/h

50%: 11.8L/h

25%: 6.5L/h


Main technical data of 160kW diesel generator set


Manufacturer:Guangxi Dingbo Generator Set Manufacturing Co.,Ltd
Genset modelDB-160GF
TypeSilent Type
Prime power:200KVA/160KW
Standby power:220KVA/176KW
Rated current:304A
Rated voltage:380V
Rated speed1500rpm
Rated frequency50Hz
Power factor:0.8lag
Phase:3 phase 4 wire
Noise level75dBA at 7 meters
Fuel Tank8 hours’ Supply
Dimension (L x W x H):3400*1400*2000 mm
Gross weight:2800kg


Two Shangchai Silent Diesel Generators Will Be Exported to Madagascar


Diesel engine specifications


Manufacturer:Shanghai New Power Aotomotive Technology Company Limited
Engine modelSC8D280D2
Prime power:185kW
Standby power:204KW
Frequency:50Hz
Speed:1500rpm
Cylinders no. & Type:6 cylinders, Inline, 4 stroke, diesel engine, water-cooled
Aspiration:Turbo charged & Air-to-air intercooled
Displacement:8.27L
GovernorElectronic speed governor
Bore x Stroke(mm):114*135mm
Compression Ratio:18:1
Start mode:Electric start
Starter motor voltage:24V DC
Type Injection System:direct injection
Oil Pan Capacity - Low / High15L-19L
Coolant Capacity - Engine Only12L
Fuel consumption-standby power100%: 49.7L/h
Fuel consumption-prime power

100%: 44.9L/h

75%: 33.5L/h

50%: 22.5L/h

25%: 12.4L/h


A standout feature of these generator sets is their ultra-quiet operation. The custom-designed soundproof enclosure, constructed from 2mm-thick galvanized steel with a corrosion-resistant powder coating, ensures exceptional durability in harsh climates. The acoustic engineering reduces noise levels to 75dB(A) at 7 meters, making these units ideal for urban areas, hospitals, hotels, or any environment where noise pollution must be minimized.

 

Both gensets are equipped with Automatic Transfer Switches (ATS), ensuring seamless transition between grid and generator power during outages. This feature guarantees uninterrupted electricity supply—a critical requirement for industries, commercial facilities, and emergency backup scenarios.

 

Why clients choose Dingbo Power?


This Madagascar order underscores Dingbo Power’s commitment to delivering tailored solutions that align with global clients' unique requirements. Our generators comply with international standards and undergo rigorous quality checks to ensure reliability in diverse applications. With over 18 years of industry expertise, a skilled engineering team, and dedicated after-sales support, we empower businesses worldwide to overcome power challenges efficiently.

 

For inquiries or to learn more about our products, contact our sales team at [email protected]. Let Dingbo Power energize your success!

Share

Contact Us

  • Add.: No. 10 Kechuang Road, High tech Zone, Nanning, Guangxi, China
  • Tel.: +86 771 5805 269
  • Fax: +86 771 5805 259
  • Cellphone: +86 134 8102 4441
                    +86 138 7819 8542
  • E-mail: [email protected]
Follow Us

Copyright © Guangxi Dingbo Generator Set Manufacturing Co., Ltd. All Rights Reserved | Sitemap

Update cookies preferences

generator set:

Emergency vs Standby Generator: What’s The Difference? Commercial Generators Trailer Mounted Water Pumps for Sale
Contact Us