Home Products News Contact Us
Home > News > 2 Sets of 400kw 500kva Diesel Generators Were Exported to Saudi Arabia

2 Sets of 400kw 500kva Diesel Generators Were Exported to Saudi Arabia

Dec. 31, 2024

On October 27, 2023, Dingbo Power started to arrange the production of two sets of prime power 400kw Cummins diesel generators for a client from Saudi Arabia. After being factory tested and certified, the generators were delivered to the client successfully. Thanks for the client’s trust and support.


Technical data of 400kw diesel gensets


Manufacturer: Guangxi Dingbo Generator Set Manufacturing Co.,Ltd.

Genset model: DB-400GF

Type: Silent type

Prime/Standby rating: 400kw/440kw

Rated voltage: 415/240V

Rated Current: 696A

Speed/frequency: 1500rpm/50Hz

Phase & Wire: 3 Phase 4 Wire

Power factor: 0.8lag

Diesel engine: Cummins QSZ13-G3

Alternator: Leroy Somer TAL-A47-C

Controller: Deep Sea DSE6120


The gensets are powered by DCEC QSZ13-G3 diesel engines with a prime/standby power of 450kw/470kw at 1500 rpm, which have high performance for tough applications. The QSZ engine was developed using Cummins unique in-house capability, adapting core technologies in electronics, fuel systems, turbo charging, filtration, and emissions.


2 Sets of 400kw 500kva Diesel Generators Were Exported to Saudi Arabia


Technical specifications of Cummins QSZ13-G3 engine


Number of Cylinders and type: 6 cylinders, Inline, 4 stroke, diesel engine, water-cooled

Bore and Stroke: 130 mm * 163 mm

Aspiration: Turbocharged & Charge Air Cooled

Displacement: 13.0 L

Fuel System: HPCR

Compression Ratio: 17:1

Governor: Electronic speed governor

Starter motor voltage: 24V DC

Total system capacity (standard pan):45.42L

Coolant Capacity (Engine Only):23.1L


The 400kw diesel gensets are housed in a soundproof enclosure, which can reduce the noise produced by the generator effectively and protect the genset from the elements such as rain and snow. The noise level is 75 dB at 7 meters. These silent diesel generators can be installed both indoors and outdoors. The genets are equipped with a 750L bottom base fuel tank, which can ensure that the generator has sufficient fuel supply to generate electricity for extended periods of time.


Understanding the generator’s power ratings before making a purchase


Before buying a diesel generator, you need to consider several factors to choose the one that can best fits your needs. It’s necessary to have a basic understanding of the prime power rating, standby power rating and continuous power rating.


Prime power rating


Prime power ratings is applicable for supplying electric power in lieu of commercially purchased power. Prime power applications must be in the form of the following two categories:


Unlimited time running prime power


Prime power is available for unlimited number of hours per year in a variable load application. Variable load should not exceed a 70% average of the prime power rating during any operating period of 250 hours.


The total operating time at 100% prime power shall not exceed 500 hours per year.


A 10% overload capability is available for a period of 1 hours within a 12 hour period of operation. Total operating time at the 10% overload power shall not exceed 25 hours per year.


Limited time running prime power


Prime power is available for a limited number of hours in a non-variable load application. It is intended for use in situations where power outages are contacted, such as in utility power curtaiment. Engine may be operated in parallel to the public utility up to 750 hours per year at power levels never to exceed the prime power rating. The customer should be aware, however, the life of any engine will be reduced by this constant high load operation. Any operation exceeding 750 hours per year at the prime power rating should use the continuous power rating.


Standby power rating


Standby power rating is applicable for supplying emergency power for the duration of the utility power outage. No overload capability is available for this rating. Under no condition is an engine allowed to operate in parallel with the public utility at the standby power rating.


This rating should be applied where reliable utility power is available. A standby rated engine should be sized for a maximum of an 80% average load factor and 200 hours of operation per year. This includes less than 25 hours per year at the standby power rating. Standby ratings should never be applied except in true emergency power outages. Negotiated power outages contracted with a utility company are not considered as emergency.


Continuous power rating


Continuous power rating is applicable for supplying utility power at a constant 100% load for an unlimited number of hours per year. No over load capability is available for this rating. This rating is approximately 70% of the prime rating.


Looking for a diesel generator for your home or business? If you are not sure which one is suitable for you, feel free to contact us today. From 20 kW to 3000 kW, Dingbo Power has a variety of generators available in different sizes to meet your power requirements.


Share

Contact Us

  • Add.: No. 10 Kechuang Road, High tech Zone, Nanning, Guangxi, China
  • Tel.: +86 771 5805 269
  • Fax: +86 771 5805 259
  • Cellphone: +86 134 8102 4441
                    +86 138 7819 8542
  • E-mail: [email protected]
Follow Us

Copyright © Guangxi Dingbo Generator Set Manufacturing Co., Ltd. All Rights Reserved | Sitemap

Update cookies preferences

generator set:

Emergency vs Standby Generator: What’s The Difference? Commercial Generators Trailer Mounted Water Pumps for Sale
Contact Us