Shangchai Engine SC25G610D2 Technical Data


◎POWER RATING


Engine Speed

Type of Operation

Engine Power

rpm

kW

Ps

1500

Prime Power

405

551

Stanby Power

445

605


◎ SPECIFICATIONS

◎ FUEL CONSUMPTION

ㅇEngine Model

SC25G610D2

ㅇPower

lit/hr

ㅇEngine Type

V-type, 4 strokes, water-cooled, Turbo charged air-to-air intercooled

25%

30.9



50%

53.6

ㅇCombustion type

Direction injection

75%

75.8

ㅇCylinder Type

Wet liner

100%

100.4

ㅇNumber of cylinders

12

110%

112.7

ㅇBore × stroke

135(5.32) × 150(5.9) mm(in.)



ㅇDisplacement

25.8 (1574) lit.(in3)



ㅇCompression ratio

16 : 1



ㅇFiring order

1-12-5-8-3-10-6-7-2-11-4-9

◎ FUEL SYSTEM


ㅇInjection timing

14.5°BTDC

ㅇInjection pump

Yijie in-line "P" type

ㅇDry weight

Approx.2080kg (4585 1b)

ㅇGovernor

Electric type

ㅇDimension

1930×1686×1872mm

ㅇFeed pump

Mechanical type

  (L×W×H)

(76×66.4×75.8 in.)

ㅇInjection nozzle

Multi hole type

ㅇRotation

Counter clockwise viewed from Flywheel

ㅇOpening pressure

240 kg/cm2 (3414 psi)

ㅇFly wheel housing

SAE NO.0

ㅇFuel filter

Full flow, cartridge type

ㅇFly wheel

SAE NO. 18

ㅇUsed fuel

Diesel fuel oil





◎ MECHANISM

◎ LUBRICATION SYSTEM

ㅇType

Over head valve

ㅇLub. Method

Fully forced pressure feed type

ㅇNumber of valve

Intake 1, exhaust 1 per cylinder

ㅇOil pump

Gear type driven by crankshaft

ㅇValve lashes at cold

Intake 0.325mm (0.0128 in.)

ㅇOil filter

Full flow, cartridge type


Exhaust 0.375mm (0.0148 in.)

ㅇOil pan capacity

High level 65 liters ( 17.16 gal.)

Low level 55 liters (14.52 gal)



ㅇAngularity limit

Front down 25 deg.

Front up 35 deg.

Side to side 35 deg.

◎ VALVE TIMING


Opening        

Close

ㅇIntake valve

20°BTDC

48°ABDC



ㅇExhaust valve

48°BBDC

20°ATDC

ㅇLub. Oil

Refer to Operation Manual





◎ COOLING SYSTEM

◎ ENGINEERING DATA

ㅇCooling method

Fresh water forced circulation

ㅇWater flow

740 liters/min @1,500 rpm

ㅇWater capacity (engine only)

48 liters ( 12.7 gal.)

ㅇHeat rejection to coolant

79 kcal/sec @1,500 rpm



ㅇHeat rejection to CAC38 m3/min @1,500 rpm

ㅇPressure system

Max. 0.5 kg/cm2 ( 7.11 psi)

ㅇAir flow

32 m3/min @1,500 rpm

ㅇWater pump

Centrifugal type driven by belt

ㅇExhaust gas flow

86 m3/min @1,500 rpm

ㅇWater pump Capacity

740 liters( 195.36 gal.)/min at 1, 500 rpm (engine)

ㅇExhaust gas temp.

650 °C @1,500 rpm

ㅇThermostat

Wax-pellet type

Opening temp. 77°C

Full open temp. 90°C

ㅇMax. permissible restrictions


Intake system

3 kPa initial

6 kPa final

ㅇCooling fan

Blower type, plastic

1100 mm diameter, 6 blades

Exhaust system

6 kPa max

ㅇMax. permissible altitude

2,000 m





◎ ELECTRICAL SYSTEM

◆ CONVERSION TABLE

ㅇCharging generator

28V×55A

in. = mm × 0.0394

lb/ft = N.m × 0.737

ㅇVoltage regulator

Built-in type IC regulator

PS = kW × 1.3596

U.S. gal = lit. × 0.264

ㅇStarting motor

24V×11kW

psi = kg/cm2 × 14.2233

kW = 0.2388 kcal/s

ㅇBattery Voltage

24V

in3 = lit. × 61.02

lb/PS.h = g/kW.h × 0.00162

ㅇBattery Capacity

200 AH

hp = PS × 0.98635

cfm = m3/min × 35.336



lb = kg × 2.20462



Shangchai SC25G610D2 engine.jpg



Alternator/AC Generator Basic Technical Parameters is given below:


Alternator Data

Output Power(KW)

385KW

Structure

One-piece

Excitation type

Brushless Self Excitation

Overload Capacity

10% overload for one hour

Insulation Class

H

Short-time Current

150%10S

Protection Class

IP22

Mode of Connection

3-phase, 4-line, neutral ground

Rated Voltage

380V/400V/415V

Power Factor

0.8Lag

Rated Frequency50 HzRated Speed1500rpm


Starlight alternator.jpg


Alternator we can supply Stamford, Leroy-somer, Marathon, Engga, Starlight and Shanghai KEPU alternator for your choice.


Starlight silent diesel generator adopts vibration isolation, noise reduction, sound insulation, sound absorption, fireproof, high temperature resistance, rainproof, anticorrosion and so on noise reduction technical measures, which greatly reduce its noise index. This series of genset has remarkable low noise performance, multi-layer shielding impedance mismatch type soundproof cover, reducing the impact of noise on users. Starlight silent generator noise level can reach 65 dB, with low fuel consumption, reliable performance and easy operation features. 


silent diesel generator.jpg

Contact Us

  • Add.: No. 10 Kechuang Road, High tech Zone, Nanning, Guangxi, China
  • Tel.: +86 771 5805 269
  • Fax: +86 771 5805 259
  • Cellphone: +86 134 8102 4441
                    +86 138 7819 8542
  • E-mail: [email protected]
Follow Us

Copyright © Guangxi Dingbo Generator Set Manufacturing Co., Ltd. All Rights Reserved | Sitemap

Update cookies preferences

generator set:

Emergency vs Standby Generator: What’s The Difference? Commercial Generators Trailer Mounted Water Pumps for Sale
Contact Us