The Dingbo 600kW Yuchai diesel generator set (Model: DB-600GF) is engineered to deliver dependable prime and standby power for mid-to-large commercial and industrial facilities. Powered by the Yuchai YC6TD1000-D30 turbocharged engine — a 19.6-liter, 6-cylinder in-line unit with ECU electronic governing — this 750kVA Yuchai generator set combines high power density with low operating costs, making it an ideal choice for hotels, office buildings, hospitals, industrial parks, and data centers.

With over 25 years of manufacturing experience and ISO 9001 certification, Dingbo Power builds each 600kW Yuchai diesel generator set to international quality standards, pairing the Yuchai engine with world-class alternator brands including Leroy-Somer, Stamford, and Marathon.


Standard Features

1. Engine: Yuchai  YC6TD1000-D30

2. Radiator 50℃ max

3. Fans are driven by belt, with safety guard

4. 24V charge alternator

5. Dry type air filter, fuel filter, oil filter

6. Alternator: single bearing alternator

7. IP23, insulation class H/H

8. Main line circuit breaker

9. Standard control panel

10. Absorber

11. Muffler

12. User manual


Application Scenarios

The 600kW output of this Yuchai diesel generator set is particularly well-matched to:

•Hotels & Resorts (150–350 room properties): Covers HVAC, elevators, kitchen equipment, and emergency lighting simultaneously

•Office Buildings & Commercial Centers: Prime or standby supply for 20,000–40,000 m² facilities

•Hospitals & Healthcare Facilities: Meets requirements for essential loads including operating theaters and ICU

•Industrial Plants & Manufacturing: Backup for CNC machinery, air compressors, and production lines

•Data Centers (Edge / Colocation): Low THD (<2%) and fast frequency recovery (<5s) protect server infrastructure

•Telecom Base Stations: Reliable prime power in off-grid or grid-unreliable regions

•Construction Sites: Provides temporary power for large-scale civil or infrastructure projects


Why Choose Dingbo's 600kW Yuchai Diesel Generator Set

1. Genuine Engine & Alternator SourcingDingbo Power is an authorized assembler with verified supply chains for Yuchai engines and brand-name alternators. You receive genuine components — not rebranded substitutes — with traceable serial numbers.

2. Factory-Direct Pricing from GuangxiOur manufacturing base is located in Nanning, Guangxi — the same province as Yuchai's engine factories. Proximity reduces logistics costs and enables tighter quality coordination during assembly.

3. Full-Spectrum CustomizationFrom voltage configuration (110V–690V) to enclosure type, ATS integration, and parallel synchronization, the DB-600GF can be tailored to project-specific requirements without minimum quantity constraints for standard configurations.

4. ISO 9001 Certified ManufacturingEvery 750kVA Yuchai diesel generator set that leaves our facility has passed a full-load test at rated power, with test certificates provided.

5. Global After-Sales NetworkDingbo provides spare parts supply, remote technical support, and on-site service coordination across Asia, Africa, the Middle East, and Southeast Asia. Warranty: 12 months or 1,000 operating hours (whichever comes first), with extended service plans available.


Request a Quote

Need a high-performance 600kW Yuchai Diesel Generator Set with reliable standby and prime power capability? Our Yuchai diesel generator sets feature efficient fuel systems, advanced control modules, low-noise operation, and flexible configurations including ATS, soundproof canopies, and parallel operation systems. Yuchai generators are widely recognized for their fuel efficiency, easy maintenance, and strong medium-to-large power performance in industrial applications.

Contact Dingbo Power directly


Key Specifications

Diesel Engine Data
Manufacturer:Yuchai
Model: YC6TD1000-D30
Prime Power:668kW
Standby Power:735kW
Rated Speed:1500(r/min)
Cycle:4 stroke
Cylinder Arrangement:6, vertical in-line
Aspiration:Exhaust gas turbocharged, air-air intercooled
Displacement:19.6L
Bore and Stroke:152*180(mm)
Compression Ratio:14:1
Governor Type:ECU
Start battery voltage:24V DC


Fuel System
Fuel Supply System:HPCR
Fuel Consumption at prime power 100%:166.6L/h
Fuel Consumption at prime power 50%:84.2L/h


Oil System
Engine oil capacity52L


Cooling System
Cooling Way:Water-cooled


Alternator Data

Manufacturer:LEROY SOMER/ STAMFORD/ SIEMENS/ MARATHON/ ENGGA/ Shanghai Stamford
Excitation Mode:Brushless and self- exciting
Number of phase and Access Act:3-phase 4-wire
Connecting Type:"Y" type connecting
Alternator Capacity:600KW/750kVA
Alternator Efficiencies:95%
Overload:(PRP)110% load can run 1h
Protection Level:IP22-IP23
Insulation Class, Temperature Rise:H/H
Telephone Influence Factor (TIF):<50
THF:<2%
Voltage Regulation, Steady State:≤±1%
Altitude:≤1000m


Genset Electrical Performance

Voltage Regulation:≥±5%
Voltage Regulation, Stead State:≤±1%
Sudden Voltage Warp (100% Sudden Reduce):≤+25%
Sudden Voltage Warp (Sudden Increase):≤-20%
Voltage Stable Time (100% Sudden Reduce):≤6S
Voltage Stable Time (Sudden Increase):≤6S
Frequency Regulation, Stead State:≤5%
Frequency Waving:≤1.5%
Sudden Frequency Warp (100% Sudden Reduce ):≤+12%
Sudden Frequency Warp (Sudden Increase):≤-10%
Frequency Recovery Time (100% Sudden Reduce):≤5S
Frequency Recovery Time (Sudden Increase):≤5S



Options

Engine

Alternator

Heater 2KW & 4KW

Anti Condensation Heater

Battery Charger 3.5A & 7A

Permanent Magnet Generator(PMG)

Water Separator

Drop CT(For Paralleling)

Daily Fuel Tank


Fuel Level Sensor


Control System

Others

Remote Control Panel

Rainproof Type

Auto Transfer Switch (ATS)

Soundproof Type

Paralleling System

Trailer Type

Open Type

Overall Size

Weight

4500(mm) *1750(mm) *2100mm)

7200(kg)

Cummins 82GFg

Soundproof Type

Overall Size

Weight

4900(mm) *2200(mm) *2600(mm)

12000(kg)


Cummins generator

Standard Control Panel
standard control panel

Dingbo Standard Control Panel uses micro processing technique integrating digital, intelligent and network techniques which can carry out functions including auto start/stop, data measure, alarming. The controller uses LCD display, optional Chinese and English display interface with operation easy and reliable. It can be widely used in all types of generator automatic control system for compact structure, advanced circuits, simple connections and high reliability


Auto Module Control Panel
auto module

Auto Module Control Panel is the configuration for nobody on duty controlling generators. This kind of panel adopts auto module control system, with large LCD display to show the menu. Features: 6110 can receive remote output signal from ATS and realize auto start and stop of generators. 6310 can realize all functions of 6110, add RS232 interface which can communicate with PC to realize remote operation. 6410 Auto Mains Failure controller, can realize all functions of 6310, furthermore can detect ATS and control directly.

Auto Parallel Control Panel
genset auto parallel controller

This new automatic parallel system adopts intelligent modules, inserted and folded installed, no need the peripheral relay and logic circuit. The main switch adopts electronic breaker or frame breaker, combined together with the generator, which is very reliable. One generator, one panel. The panel can be used both for singly and parallel. It is only need to parallel generator with such panel when the capability needs to be enlarged in the future.



625kVA/500kW Yuchai Diesel Generator Set
438kVA/350kW Yuchai Diesel Generator Set
375kVA/300kW Yuchai Diesel Generator Set

Contact Us

  • Add.: No. 10 Kechuang Road, High tech Zone, Nanning, Guangxi, China
  • Tel.: +86 771 5805 269
  • Fax: +86 771 5805 259
  • Cellphone: +86 134 8102 4441
                    +86 138 7819 8542
  • E-mail: [email protected]
Follow Us

Copyright © Guangxi Dingbo Generator Set Manufacturing Co., Ltd. All Rights Reserved | Sitemap

Update cookies preferences

generator set:

Emergency vs Standby Generator: What’s The Difference? Commercial Generators Trailer Mounted Water Pumps for Sale
Contact Us