3 Check that the filter sealing surface is clean. 4 Install a new filter (3) and a new O-ring (2). 5 Install the filter cover (1) and filter. Tightening torque: 40 Nm (29.5 lbf. ft.) 6 Fill with engine oil; refer to Administration page 16. 7 Start the engine and check that there is oil pressure. 8 Check that no leakage is present. 9 Stop the engine and check the oil level after a couple of minutes.
Maintenance is necessary and important for a engine or diesel generator. Regular maintenance helps to prolong the service life of the machine.
Start the engine and check the oil pressure. If the oil pressure measurement shows that the pressure is below the specified minimum value, continue fault tracing by checking the oil filters. If the oil pressure measurement using an external pressure sensor shows that the pressure is within tolerances, but the regular engine pressure sensor does not, replace the regular pressure sensor.
8 Remove the upper bearing shell by putting a pin in the crankshaft oil hole and rolling the bearing shell out by turning the crankshaft in the direction of rotation with a cranking tool. 9 Clean and check the bearing seats, bearing caps and bearing shells. The bearing surfaces must be completely smooth. Repolish them if there are minor scratches. If a bearing has seized, the cause must be determined