Diesel Generator Technical Specifications
Manufacturer:Guangxi Dingbo Generator Set Manufacturing Co.,Ltd
Genset modelDB-64GF
TypeSilent type
Power: 64KW/80KVA
Rated current:122A
Rated voltage:380/220V
Rated speed/frequency1500rpm/50Hz
Power factor:0.8lag
Phase:3 phase 4 wire
MCCB Breaker250A
Fuel typeLight diesel
Fuel consumption@25% / 50% / 75% / 100%(L/h)5.5/10/14.6/18.7
Fuel consumption@110% (L/h)20.4
Stable voltage regulation rate≤±0.5%
Volatility≤±0.25%
Transient voltage regulation rate≤+20~-15%
Steady state frequency regulation≤±0.5%
Transient frequency adjustmentrate≤±7%
Frequency adjustment rate≤±1%
Frequency stability time  1s
Voltage stability time≤1s
Daily fuel tank for silent type185L
Noise level for silent type75dBA at 7 meters, 87dBA at 1m
Dimension( L x W x H) for silent type2700*1240*1790mm
Weight for silent type1400kg


Engine Specifications: Shangchai 4ZTAA4.1-G31


Engine Technical Specifications
Manufacturer:SDEC
Engine model4ZTAA4.1-G31
Prime power: 74KW
Standby power:81KW
Frequency/Speed:50Hz/1500RPM
Cylinders no. & Type:4 cylinders, In line, 4 stroke, diesel engine, water-cooled with radiator with fan
Aspiration:Turbo charged and intercooled
Displacement:4.1L
Compression ratio18:1
GovernorElectric speed control
Bore x Stroke(mm):105 x 118
Start mode:Electric start
Starter motor:24V DC, negative ground
Fuel System:Direct injection
Oil Pan Capacity High/Low10L/8L
Maximum oil temperature121℃
Cooling wayWater-cooled
Engine coolant capacity8.54L
Standard thermostat (modulating) range72-82℃
Maximum Top Tank Temperature for Standby / Prime Power104/100℃


Alternator Specifications


Alternator
ManufacturerShanghai Stamford Power Equipment Co.,Ltd
Alternator modelShanghai Stamford GR225G
Prime power64KW
TypeSynchronous alternator
Rated Voltage:380/220V
Frequency/Speed:50Hz/1500RPM
Wire connecting methodY type, 3 phase 4 wire
Power Factor:0.8lag
Efficiency:95.2%
Regulator:AVR
Rotor:Single/double bearing
Exciter type:Brushless Self-Excited
Recovery time(Tr)1s
Waveform : TIF<50
Waveform : THF<2%
Winding Pitch2/3
Voltage regulation:± 1.0 %
Protection:IP23
Insulation classH
Temperature rise grade:H
DutyContinuous
Overload110% rated load for1 hour per12 hours


Control Panel


Cloud Remote Control/ Monitoring System


Manufacturer: SmartGen

ModelHGM6110N-4G-G

Single unit automation, Remote signal start/stop

 

(Our cloud service management system can let you remote control(start/stop) and monitor generator set by App on computer or mobile phone any time any where, more efficient and cost-effective management of your generator set)


Operating Environment: 


Operating temperature:-25℃~+70℃
Relative humidity:95%
Operating voltage:DC24V(range: 8-35V)
PanelSilicone Rubber
IP RatingIP65
FunctionAuto start
Built-in Cloud MonitoringYes
SMSYes
Working ModeAuto/Stop/Manual
Alarm ProtectionWarning/Shutdown


Product Features:


Automatic controller has network communication module inside, which can realize genset access to internet. After controller logging in cloud server, the unit data information (include GPS positioning, altitude, etc.) will be uploaded in real time to the corresponding cloud server. Users can monitor the genset and inquire the genset running status, the event log, as well as configure the parameters via cloud server by phone APP (ISO or Android) and computer terminal equipment. The network communication module also has SMS function.

 

Automatic controller uses 32-bit microprocessor which can achieve precision measurement, value adjustment, timing and threshold setting etc.. All the parameters can be configured from front panel or use USB interface (or RS485 interface) to adjust via PC. It can be widely used in all types of automatic control system for its compact structure, simple connections and high reliability.

 

Automatic controller, integrating digital, intelligent and network techniques, is used for automatic control and monitoring system of genset. It can carry out functions of automatic start/stop, data measurement, alarm protection and three “remote” (remote control, remote measure and remote communication). The controller uses LCD display, optional display interface including Chinese, English, Spanish, Russian, Portuguese, Turkish, Polish and French with easy and reliable operation. 


Feature


1. Remote control(start/stop)

 

Display real time status for engine and alternator.

 

Support automatic/manual stop/start, reset, close and other operations.

 

Support power generation closing / opening, utility closing / opening and other operations.

 

All operations need to be authenticated by face or control code.

 

2. Remote monitoring

 

Diesel engine: Speed, water temperature, oil pressure, liquid level, battery voltage, charging voltage etc.

 

Generator: Power, power factor, three-phase current, three-phase voltage, frequency, etc.

 

3. Real time data

 

Diesel engine: including all detailed data such as accumulated running time, maintenance countdown, etc

 

Generator: including the accumulated electric energy and other detailed data that can be collected and analyzed.

 

Mains / bus: three phase voltage, single phase voltage, frequency, phase, etc.

 

Various input and output, programmable access, etc.

 

4. Save the operation data of the genset in recent 3 months.

 

5. Genset daily running hours, total running hours for easier maintenance.

 

6. Record all information of genset, such as power, voltage, current, model, brand, supplier etc.

 

7. Support multi genset management and parallel genset management.

 

8.Multi machine view, single machine control, unlimited number, multi person management.

 

Below protection shut down causes are included:

 

The main characteristics are as follows:

 

132*64 LCD display with backlight, eight optional languages interface (Chinese, English, Spanish, Russian, Portuguese, Turkey, Polish and French), push-button operation;

 

Acrylic screen, improved wearable and scratch resistance property;  

 

Silica-gel panel and keys can well adapt to higher and lower temperature;

 

With RS485 communication port, can achieve “three remote” functions via MODBUS protocol (available for the controller with RS485 port);

 

With CANBUS port which can be connected to EFI with J1939, it not only can monitor frequently-used data (such as water temperature, oil pressure, rotated speed and fuel consumption, etc.) but also can control start, stop, high speed and low speed (controller with CANBUS port is needed) via CANBUS port;

 

Adapt to 3P4W, 3P3W, 1P2W and 2P3W (120V/240V), 50Hz/60Hz AC power system;

 

Can collect and display 3 phase voltage, 3 phase current, frequency, power parameter of mains/gens;

 

Mains                                 Generator

 

Line voltage (Uab, Ubc, and Uca)        Line voltage (Uab, Ubc, and Uca)

 

Phase voltage (Ua, Ub, and Uc)         Phase voltage (Ua, Ub, and Uc)

 

Frequency   HZ                      Frequency   HZ

 

Phase Sequence                      Phase Sequence

 

Load

 

Current   IA, IB, IC

 

Active power kW

 

Reactive power kvar

 

Apparent power kVA

 

Power factor PF

 

Generator accumulated energy kWh

 

Output percentage with load %

 

Mains have functions of over/under voltage and loss of phase; Gens have functions of over/under voltage, over/under frequency, over current and over power;

 

Precision measure and display of parameters about engine,

 

Temp. (WT),           °C/ °F

 

Oil pressure (OP),      kPa/psi/bar

 

Fuel level (FL),         %         Fuel remains     L

 

Speed (SPD),          r/min

 

Battery Voltage (VB),    V

 

Charger Voltage (VD),   V

 

Accumulative running hours

 

Accumulative start times

 

Control protection: Automatic start/stop of diesel genset, close/open (ATS control) and perfect failure display and protection;

 

With ETS, idle speed control, pre-heat control, speed droop/raising control, all of them are relay output;

 

Parameter setting: Allow user to modify setting and store them in internal EEPROM memory. The parameters cannot be lost even when power off. All of parameters can be set not only from the front panel, but also use USB interface (or PS485 interface) to adjust them via PC.;

 

Multi sensors of temperature, pressure and fuel level can be used directly, parameters can be defined by user;

 

Multi conditions of crank disconnect (speed, oil pressure, frequency) can be selected;

 

With emergency start function;

 

With flywheel teeth numbers automatic identification function;

 

Power supply range: (8~35)VDC, accommodating to different starting battery volts;

 

Connect to cloud server through 4G Wi-Fi;

 

With SMS function, alarm information can be sent by the set 5 phone numbers, and can control the genset and inquire the genst status by SMS;

 

With GPS positioning function to obtain the genset position to realize the positioning of genset;

Applied JSON format network data communication protocol to realize upload when genset data changes, the compression algorithm is adopted at the same time, significantly reduces the network flow, and the alarm data can be uploaded to server immediately;

 

With maintenance function. Types (date or running time) can be selected and actions (warning or alarm shutdown) can be set when maintenance time out;

 

Event log, real-time clock, scheduled start & stop pump unit (can be set as start pump unit once a day/week/month whether with load or not);

 

Add rubber gasket between shell and controller screen, the waterproof can reach IP65;

 

Controller is fixed by metal fixing clips;


Modular design, flame-retardant ABS shell, embedded mounting, compact structure and easy installation.


80kVA/64kW Shangchai Diesel Generator Set
100kVA/80kW Shangchai Diesel Generator Set
68kVA/54kW Shangchai Diesel Generator Set

Contact Us

  • Add.: No. 10 Kechuang Road, High tech Zone, Nanning, Guangxi, China
  • Tel.: +86 771 5805 269
  • Fax: +86 771 5805 259
  • Cellphone: +86 134 8102 4441
                    +86 138 7819 8542
  • E-mail: [email protected]
Follow Us

Copyright © Guangxi Dingbo Generator Set Manufacturing Co., Ltd. All Rights Reserved | Sitemap

Update cookies preferences

generator set:

Emergency vs Standby Generator: What’s The Difference? Commercial Generators Trailer Mounted Water Pumps for Sale
Contact Us