Home Products News Contact Us
Home > Products > Generator Sets > Shangchai > 1500kVA/1200kW Shangchai Diesel Generator Set
1500kVA/1200kW Shangchai Diesel Generator Set

1500kVA/1200kW Shangchai Diesel Generator Set

When industrial facilities, critical infrastructure operators, and large commercial projects need power at the megawatt scale, the 1500kVA Shangchai diesel generator set powered by the SDEC 12KTA58-G35 engine is one of the most proven and cost-effective configurations available from China. Manufactured by Guangxi Dingbo Power — a specialist genset integrator with direct factory relationships with SDEC (Shanghai Diesel Engine Co., Ltd.) — this unit combines a high-displacement, electronically controlled V12 diesel engine with your choice of world-class alternator brands, all assembled and load-tested before shipment.


Standard Features

1. Engine: Shangchai 12KTA58-G35

2. Radiator 50℃ max

3. Fans are driven by belt, with safety guard

4. 24V charge alternator

5. Dry type air filter, fuel filter, oil filter

6. Alternator: single bearing alternator

7. IP23, insulation class H/H

8. Main line circuit breaker

9. Standard control panel

10. Absorber

11. Muffler

12. User manual


Complete Technical Specifications

Diesel Engine Data
Manufacturer:Shangchai
Model:12KTA58-G35
Prime Power:1420kW
Standby Power:1560kW
Rated Speed:1500(r/min)
Cycle:4 stroke
Cylinder Arrangement:12, V-type
Aspiration:Turbocharged, Aftercooled
Displacement:57.2L
Bore and Stroke:170*210(mm)
Compression Ratio:18:1
Governor Type:ECU
Start battery voltage:24V DC


Fuel System
Fueling systemHPCR
Conbustion System:Direct Injection
100% ( Prime Power) Load:325.3L/hr
50% ( Prime Power) Load:175.7 L/hr


Oil System
Oil pan capacity-High level/Low levl:313/222L


Cooling System
Cooling Way:Water-cooled
Coolant capacity-engine+water-to-air intercooler194.4L


Alternator Data
Manufacturer:LEROY SOMER/ STAMFORD/ SIEMENS/ MARATHON/ ENGGA/ Shanghai Stamford
Excitation Mode:Brushless and self- exciting
Number of phase and Access Act:3-phase 4-wire
Connecting Type:"Y" type connecting
Alternator Capacity:1200KW/1500kVA
Alternator Efficiencies:95%
Overload:(PRP)110% load can run 1h
Protection Level:IP22-IP23
Insulation Class, Temperature Rise:H/H
Telephone Influence Factor (TIF):<50
THF:<2%
Voltage Regulation, Steady State:≤±1%
Altitude:≤1000m


Genset Electrical Performance
Voltage Regulation:≥±5%
Voltage Regulation, Stead State:≤±1%
Sudden Voltage Warp (100% Sudden Reduce):≤+25%
Sudden Voltage Warp (Sudden Increase):≤-20%
Voltage Stable Time (100% Sudden Reduce):≤6S
Voltage Stable Time (Sudden Increase):≤6S
Frequency Regulation, Stead State:≤5%
Frequency Waving:≤1.5%
Sudden Frequency Warp (100% Sudden Reduce ):≤+12%
Sudden Frequency Warp (Sudden Increase):≤-10%
Frequency Recovery Time (100% Sudden Reduce):≤5S
Frequency Recovery Time (Sudden Increase):≤5S



Options

Engine

Alternator

Heater 2KW & 4KW

Anti Condensation Heater

Battery Charger 3.5A & 7A

Permanent Magnet Generator(PMG)

Water Separator

Drop CT(For Paralleling)

Daily Fuel Tank


Fuel Level Sensor


Control System

Others

Remote Control Panel

Rainproof Type

Auto Transfer Switch (ATS)

Soundproof Type

Paralleling System

Trailer Type

Open Type

Overall Size

Weight

5350(mm) *2555(mm) *2785(mm)

13500(kg)

Cummins 82GFg

Soundproof Type

Overall Size

Weight

9000(mm) *2438(mm) *2896(mm)

20800(kg)


Cummins generator

Standard Control Panel
standard control panel

Dingbo Standard Control Panel uses micro processing technique integrating digital, intelligent and network techniques which can carry out functions including auto start/stop, data measure, alarming. The controller uses LCD display, optional Chinese and English display interface with operation easy and reliable. It can be widely used in all types of generator automatic control system for compact structure, advanced circuits, simple connections and high reliability


Auto Module Control Panel
auto module

Auto Module Control Panel is the configuration for nobody on duty controlling generators. This kind of panel adopts auto module control system, with large LCD display to show the menu. Features: 6110 can receive remote output signal from ATS and realize auto start and stop of generators. 6310 can realize all functions of 6110, add RS232 interface which can communicate with PC to realize remote operation. 6410 Auto Mains Failure controller, can realize all functions of 6310, furthermore can detect ATS and control directly.

Auto Parallel Control Panel
genset auto parallel controller

This new automatic parallel system adopts intelligent modules, inserted and folded installed, no need the peripheral relay and logic circuit. The main switch adopts electronic breaker or frame breaker, combined together with the generator, which is very reliable. One generator, one panel. The panel can be used both for singly and parallel. It is only need to parallel generator with such panel when the capability needs to be enlarged in the future.


Applications: Where the 1500kVA Shangchai Diesel Generator Set Is Deployed

The 1200kW / 1500kVA power range occupies a critical tier in industrial power infrastructure — large enough to serve as prime power for mid-scale facilities, or as redundant backup for large critical operations. Typical deployments include:

Critical Infrastructure & Healthcare Hospitals, dialysis centres, and surgery suites require uninterrupted power within seconds of a mains failure. The 5–6 second start-up time and AMF control panel of this 1500kVA Shangchai diesel generator set meet the requirements of most healthcare power backup standards. The premium alternator options (Leroy-Somer, Stamford) ensure the clean sine wave quality required by sensitive medical imaging equipment.

Data Centres & Telecommunications Data centres operating N+1 or 2N redundancy configurations use this power tier for individual PDU-level backup. The <2% THF and ≤±1% steady-state voltage regulation meet the power quality requirements of server infrastructure. The parallel control panel option enables multi-unit configurations for larger data halls.

Manufacturing & Heavy Industry Factories, cement plants, steel mills, and processing facilities use the 1200kW prime power configuration as a continuous prime power source in areas with unreliable grid supply. The 12,000-hour overhaul interval and 195 g/kW·h fuel economy reduce operating costs over multi-year production cycles.

Construction & Infrastructure Projects Large construction sites — tunnels, bridges, stadiums, airport terminals — use the trailer-mounted or containerised versions of this 1500kVA Shangchai diesel generator set for temporary site power. The 50°C ambient radiator rating handles Middle East, Southeast Asian, and African site conditions without derating.

Hotels, Resorts & Commercial Real Estate Luxury hotel properties and commercial towers in markets with unreliable grid supply (Southeast Asia, West Africa, South Asia) use this power tier for full-facility backup covering HVAC, elevators, and kitchen operations simultaneously.

Mining & Remote Resource Operations The SDEC engine's three-stage swirl air filtration system and high-vacuum exhaust injection design make this unit particularly suited for dusty mining environments where lesser-filtered engines suffer accelerated wear.


Why Source from Dingbo Power?

Guangxi Dingbo Generator Set Manufacturing Co., Ltd. is not a trading company. We are a manufacturer located at No. 10 Kechuang Road, High-tech Zone, Nanning, Guangxi, China — with our own production floor, assembly line, and load test facilities.


Contact us

Looking for a reliable 1500kVA Shangchai diesel generator set for large-scale industrial and commercial power applications? The 1200kW Shangchai generator is engineered to deliver stable output, high fuel efficiency, and dependable performance for factories, hospitals, data centers, construction projects, and critical backup power systems. Powered by a high-performance Shangchai engine, this generator set is designed for both prime and standby power applications in demanding environments.

Contact us today to get customized generator solutions tailored to your project requirements

1500kVA/1200kW Shangchai Diesel Generator Set


1250kVA/1000kW Shangchai Diesel Generator Set
1000kVA/800kW Shangchai Diesel Generator Set
900kVA/720kW Shangchai Diesel Generator Set

Contact Us

  • Add.: No. 10 Kechuang Road, High tech Zone, Nanning, Guangxi, China
  • Tel.: +86 771 5805 269
  • Fax: +86 771 5805 259
  • Cellphone: +86 134 8102 4441
                    +86 138 7819 8542
  • E-mail: [email protected]
Follow Us

Copyright © Guangxi Dingbo Generator Set Manufacturing Co., Ltd. All Rights Reserved | Sitemap

Update cookies preferences

generator set:

Emergency vs Standby Generator: What’s The Difference? Commercial Generators Trailer Mounted Water Pumps for Sale
Contact Us