Home Products News Contact Us
Home > News > Which Parts of Diesel Generators Are Not Suitable to Apply Butter?

Which Parts of Diesel Generators Are Not Suitable to Apply Butter?

Aug. 05, 2023

Regarding the question of which parts of diesel generators are not suitable for butter, it is necessary to know that butter is widely used in diesel engines to protect the body, but it should not be used indiscriminately, otherwise it will constitute undesirable consequences, and even have adverse effects and damage the body.

Perkins generator 100kw 2250kva Cummins Diesel Generator Set

Grease on dry cylinder liners of diesel engines will cause diesel engines to overheat and affect normal operation. The reason is that when the engine is operating at a normal temperature, the cylinder liner will expand due to heat, and the cylinder block seat hole will expand less due to the lower temperature of the cooling water effect. The surface of the dry cylinder liner is closely attached to the seat hole to conduct heat dissipation. The grease on the surface of the cylinder liner prevents the outstanding touch of the two surfaces and prevents normal heat dissipation.


Cylinder heads and cylinder gaskets should not be greased to enhance the sealing performance. The reason is that after the cylinder head nut is tightened, a part of the butter will be squeezed into the cylinder. When the diesel engine is operating, this part of the butter will be burned into charcoal at high temperature, and it will accumulate on the top of the cylinder piston. Part of the butter will be squeezed out of the cylinder and wasted. After the temperature of the diesel engine rises, the oil film between the cylinder head and the cylinder head gasket, and the surface of the cylinder head and the cylinder block will melt and disappear due to the increase in temperature, which will cause the cylinder head nut to return. Loose, causing air leakage and oil leakage, which will damage the cylinder head gasket. It may also be difficult to disassemble the cylinder head and cylinder head gasket due to high temperature and grease coking.


The above is what Dingbo introduced for you about which parts of diesel generators are not suitable for buttering. If you have any questions about this, you need to know. Welcome everyone to consult our website of Dingbo, and we will have professional people explain it for you.


Dingbo Power was founded in 2006 and is one of the earliest manufacturers of generators and diesel generator sets in China. If you want get more information, welcome send email to [email protected] we will pay highly attention on your question.

Share

Contact Us

  • Add.: No. 10 Kechuang Road, High tech Zone, Nanning, Guangxi, China
  • Tel.: +86 771 5805 269
  • Fax: +86 771 5805 259
  • Cellphone: +86 134 8102 4441
                    +86 138 7819 8542
  • E-mail: [email protected]
Follow Us

Copyright © Guangxi Dingbo Generator Set Manufacturing Co., Ltd. All Rights Reserved | Sitemap

Update cookies preferences

generator set:

Emergency vs Standby Generator: What’s The Difference? Commercial Generators Trailer Mounted Water Pumps for Sale
Contact Us