In December 2024, a valued client from the Middle East ordered two sets of 400kW silent-type diesel generator sets from Dingbo Power. Designed for primary power applications, these units exemplify cutting-edge engineering and adaptability to harsh environmental conditions, reinforcing Dingbo Power’s growing reputation as a global provider of reliable power solutions.


Customized configuration for optimal performance


The ordered generator sets feature a robust configuration tailored to meet the client’s demanding operational needs. Below are the main technical data of the 400kW diesel generating sets.


Manufacturer: Guangxi Dingbo Generator Set Manufacturing Co.,Ltd.

Genset model: DB-400GF

Type: Silent type

Prime Power: 500KVA/400KW

Standby power: 550KVA/440KW

Rated voltage: 400V

Rated Current: 720A

Speed/frequency: 1500rpm/50Hz

Power factor: 0.8lag

Phase & Wire:3 Phase 4 Wire

Diesel engine: Cummins KTA19-G4

Alternator: Shanghai Stamford GR355D

Controller: SmartGen HGM7220N

Base bottom fuel tank: 8 hours operation

Noise level: 75dBA at 7 meters

Capacity of ATS: 800A


Two Sets of 400kW Cummins Silent Diesel Generators Were Exported to Iran


Main diesel engine technical specifications


Manufacturer:Chongqing Cummins Engine Co.,Ltd
Engine modelKTA19-G4
Prime power:448kW
Standby power:504KW
Frequency:50Hz
Speed:1500rpm
Cylinders no. & Type:6 cylinders, In line, 4 stroke, diesel engine, water-cooled
Aspiration:Turbocharged , Aftercooled
Displacement:19L
Compression ratio:13.9:1
GovernorElectronic speed governor
Bore x Stroke(mm):159x159
Start mode:Electric start
Starter motor voltage:24V DC
Type Injection System:direct injection Cummins PT pump
Oil Pan Capacity (Option OP4019)-High37.9L
Total System Capacity (Excluding By-Pass Filter)50L-84.4L
Coolant Capacity-After-cooler Only23L
Fuel consumption at standby power @100%:100%:204g/kW.h
Fuel consumption at Prime power @25% / 50% / 75% / 100%:135g/kW.h / 192g/kW.h / 207g/kW.h / 203g/kW.h


Main alternator technical specifications


ManufacturerShanghai Stamford Power Equipment Co.,Ltd
Alternator modelGR355D
Prime power400KW(500kVA)
Rated Voltage:400V
Frequency50Hz
Speed:1500rpm
Wire connecting methodY type, 3 phase 4 wire
Power Factor:0.8lag
Efficiency:94.3%
Voltage Regulator:AVR
Rotor:Single/double bearing
Exciter type:Brushless self excitation
Recovery time(Tr)1s
Waveform : TIF<50
Waveform : THF<2%
Voltage Regulation, Steady State:±1%
Protection:IP22
Insulation classH
Temperature rise grade:H


Controller


Manufacturer: SmartGen

Model: HGM7220N


The HGM7220N series generator set controller can be used for automatic control of a single generator set, and can achieve single machine self start/AMF/synchronous switching/cloud monitoring functions. It is equipped with a built-in network communication module, which can connect the generator set to the Internet.


Users can monitor the generator set in real time through mobile apps (IOS or Android system), computers and other terminal devices, and query the operating status and historical records of the generator set. At the same time, the controller parameters can be configured through the cloud server. The network communication module also has SMS function.


Innovative design for challenging environments


Based on the client’s operational needs in the middle east's arid climate, Dingbo Power engineers implemented specialized modifications to the silent enclosures of generator sets:


Enhanced cooling system: Expanded air intakes combined with high-efficiency radiators capable of maintaining optimal temperatures at 50℃ ambient conditions.


Dual-protection filter mesh: Reinforced insect and sand-proof filters at intake points to safeguard internal components from airborne particulates common in desert regions.


Noise reduction: The soundproof enclosures and acoustic absorbing materials  reduce the noise levels of the gensets to 75dB(A), making the units suitable for noise-sensitive environments like urban facilities or hospitals.


To enhance operational safety, both the generator sets are equipped with an 800A Automatic Transfer Switch (ATS) mounted directly on the soundproof enclosures. This integration streamlines installation while ensuring swift transitFion between grid and generator power during outages.


For more details about Dingbo Power’s generator sets or to discuss customized projects, contact our export team at [email protected].


Share

Contact Us

  • Add.: No. 10 Kechuang Road, High tech Zone, Nanning, Guangxi, China
  • Tel.: +86 771 5805 269
  • Fax: +86 771 5805 259
  • Cellphone: +86 134 8102 4441
                    +86 138 7819 8542
  • E-mail: [email protected]
Follow Us

Copyright © Guangxi Dingbo Generator Set Manufacturing Co., Ltd. All Rights Reserved | Sitemap

Update cookies preferences

generator set:

Emergency vs Standby Generator: What’s The Difference? Commercial Generators Trailer Mounted Water Pumps for Sale
Contact Us