Today we will briefly introduce to you the problem of exhaust gas treatment of Volvo diesel generators.


There is a small amount of exhaust gas discharged from the generator during use. If the exhaust gas is directly discharged, it will cause certain pollution to the surrounding environment. According to environmental protection requirements, it is also in order to further improve the environmental quality around the use of Volvo diesel generators. Pollutants include: nitrogen oxides, carbon monoxide, particulate matter, sulfide, etc. So be sure to deal with the exhaust gas of Volvo diesel generators.


deutz hatz cummins perkins volvo generator


The conventional practice is to use the swirl plate water washing and spraying method, and use the swirl plate type spray tower. The gas moves from bottom to top in the tower at high speed and contacts with the washing liquid sprayed from top to bottom. The swirl plate can increase the gas-liquid contact area and contact time, so that the exhaust gas and water can be fully contacted in the tower and on the plate surface. The pollutant carbon black in the exhaust gas is fully adsorbed by the water during the contact with the spray water and can be purified; the gaseous pollutants such as NOx and SO2 in the exhaust gas can be made alkaline by adding a certain proportion of NaOH to the spray water. , During the spraying process, when the water contacts the exhaust gas, a chemical reaction occurs, so that the gaseous pollutants such as NOx and SO2 are neutralized to achieve a good treatment effect. The equipment does not need to be cleaned during the entire exhaust gas purification process, the spray water used can be recycled, automatic control can be realized, and the operation is simple.


However, no matter which method is adopted, the following requirements must be paid attention to in the design: The design and construction of the Volvo diesel generator exhaust gas treatment project should not only comply with this technical specification, but also comply with the relevant current national mandatory standards. The treatment scale and treatment process of the Volvo diesel generator exhaust gas treatment project should be determined according to the type, concentration and treatment requirements of the gas pollutants in the exhaust gas of the Volvo diesel generator of the enterprise, so as to protect the environment, be economically reasonable and technically reliable. The selection of the treatment engineering technical scheme should meet the requirements of the approval document of the environmental impact assessment report, and the exhaust gas of Volvo diesel generators should be stably met the relevant national and local emission standards after treatment.


Guangxi Dingbo Power was founded in 2006 and is one of the earliest manufacturers of generators and diesel generator sets in China. If you want get more information, please feel free to send email to [email protected] we will pay highly attention on your question.

Share

Contact Us

  • Add.: No. 10 Kechuang Road, High tech Zone, Nanning, Guangxi, China
  • Tel.: +86 771 5805 269
  • Fax: +86 771 5805 259
  • Cellphone: +86 134 8102 4441
                    +86 138 7819 8542
  • E-mail: [email protected]
Follow Us

Copyright © Guangxi Dingbo Generator Set Manufacturing Co., Ltd. All Rights Reserved | Sitemap

Update cookies preferences

generator set:

Emergency vs Standby Generator: What’s The Difference? Commercial Generators Trailer Mounted Water Pumps for Sale
Contact Us