In late December 2024, a valued client in Nepal ordered 3 sets of Cummins silent diesel generators from Dingbo Power. This order, consisting of one 150kW and two 200kW generator sets, underscores the growing international recognition of Dingbo Power as a trusted provider of reliable power solutions.

 

The Nepalese customer selected our Cummins-powered generator sets, renowned for their durability and efficiency. Each unit is equipped with a Stamford alternator and a Deep Sea controller, ensuring stable and intelligent power management.

 

Our silent generator sets are built with 2mm thick galvanized steel for enhanced durability and corrosion resistance. To meet the customer’s branding requirements, we customized the canopies by spraying their logo on the exterior. For ease of transportation and installation, the silent enclosures are designed with forklift slots at the bottom for smooth ground handling and lifting lugs on top for secure crane-assisted movements.

 

 

Three Sets of Cummins Diesel Generators Sets Were Exported to Nepal


Main technical data of 150kW diesel generator set

 

Manufacturer: Guangxi Dingbo Generator Set Manufacturing Co.,Ltd.

Genset model: DB-150GF

Type: Silent type

Prime Power: 150KW/188KVA

Standby power: 165KW/206KVA

Rated voltage: 400/230V

Rated Current: 270A

Speed/frequency: 1500rpm/50Hz

Power factor: 0.8lag

Phase & Wire:3 Phase 4 Wire

Diesel engine: Cummins QSL8.9-G2

Alternator: Original Stamford UCI274H14

Controller: Deep Sea DSE7320

Base bottom fuel tank: 8 hours operation

Noise level: 72dBA at 1 meter

Capacity of ATS: 300A


Diesel engine specifications:


Manufacturer:Dongfeng Cummins Engine Co.,Ltd
Engine modelQSL8.9-G2
Prime power:206KW
Standby power:226KW
Frequency/Speed:50Hz/1500RPM
Cylinders no. & Type:6 cylinders, In line, 4 stroke, diesel engine, water-cooled with radiator with fan
Aspiration:Turbocharged ,Charged Air Cooled
Displacement:8.9L
Compression ratio17.73:1
GovernorElectronic speed control
Bore x Stroke(mm):116.5 x 144.5mm
Start mode:Electric start
Starter motor:24V DC, negative ground
Fuel System:Direct injection
Total Oil System Capacity28.1L
Cooling wayWater-cooled
Engine Coolant Capacity11.1L
Standard Thermostat (Modulating) Range82~95℃
Maximum Oil Temperature121℃
Fuel consumption-standby power@100%59L/h
Fuel consumption-prime power@25% / 50% / 75% / 100%16L/h / 31L/h / 45L/h / 55L/h


Main technical data of 200kW diesel generator sets

 

Manufacturer: Guangxi Dingbo Generator Set Manufacturing Co.,Ltd.

Genset model: DB-200GF

Type: Silent type

Prime Power: 200KW/250KVA

Standby power: 220KW/275KVA

Rated voltage: 400/230V

Rated Current: 360A

Speed/frequency: 1500rpm/50Hz

Power factor: 0.8lag

Phase & Wire:3 Phase 4 Wire

Diesel engine: Cummins 6LTAA8.9-G2

Alternator: Original Stamford UCDI274K14

Controller: Deep Sea DSE8610

Base bottom fuel tank: 8 hours operation

Noise level: 75dBA at 1 meter

Capacity of ATS: 400A

 

Diesel engine specifications:

 

Manufacturer:Dongfeng Cummins Engine Co.,Ltd
Engine model6LTAA8.9-G2
Prime power:220KW
Standby power:240KW
Frequency/Speed:50Hz/1500RPM
Cylinders no. & Type:6 cylinders, In line, 4 stroke, diesel engine, water-cooled with radiator with fan
Aspiration:Turbocharged ,Charged Air Cooled
Displacement:8.9L
Compression ratio16.6:1
GovernorElectronic speed control
Bore x Stroke(mm):114 x 145mm
Start mode:Electric start
Starter motor:24V DC, negative ground
Fuel System:Direct injection
Minimum Required Lube Oil System Capacity27.6L
Cooling wayWater-cooled
Engine Coolant Capacity11.2L
Standard Thermostat (Modulating) Range82~93℃
Maximum Oil Temperature121℃
Fuel consumption-standby power(100%):58L/h
Fuel consumption-prime power @25% / 50% / 75% / 100%15L/h / 27L/h / 39L/h / 53L/h


The 150kW diesel generator features a noise level of 72dB at 1 meter, ideal for environments requiring low disturbance. It comes with an 8-hour base fuel tank for extended operation. With a slightly higher noise level of 75dB at 1 meter, the 200kW silent gensets include a 12-hour base fuel tank, making them perfect for longer operational demands.

 

We extend our gratitude to our Nepalese partner for their trust and look forward to further collaborations. At Dingbo Power, we continue to empower industries worldwide with efficient, quiet, and dependable generator solutions.

 

For inquiries about our silent generator sets or other power products, feel free to contact us today!



Share

Contact Us

  • Add.: No. 10 Kechuang Road, High tech Zone, Nanning, Guangxi, China
  • Tel.: +86 771 5805 269
  • Fax: +86 771 5805 259
  • Cellphone: +86 134 8102 4441
                    +86 138 7819 8542
  • E-mail: [email protected]
Follow Us

Copyright © Guangxi Dingbo Generator Set Manufacturing Co., Ltd. All Rights Reserved | Sitemap

Update cookies preferences

generator set:

Emergency vs Standby Generator: What’s The Difference? Commercial Generators Trailer Mounted Water Pumps for Sale
Contact Us