The turbochargers used in the turbocharger model of the generator set are all radial exhaust turbochargers. The oil of the turbocharger is drawn from the main oil passage of the engine. After lubricating and cooling the turbocharger, the oil is directly returned to the lower part of the crankcase.


deutz hatz cummins perkins volvo


1. Ensuring good lubrication is very important to the work of the turbocharger, so it is necessary to clean or replace the oil filter regularly. As the turbine wheel rotates at high speed, dirty oil or poor lubrication can cause damage to the turbocharger.


2. The supercharger works at a very high speed (about 70000 ~ 0000r/min), so after the diesel engine is started, it should be properly idling (about 5 minutes, and can be appropriately shortened when it is stopped for a short time) before loading. When the diesel engine is running at high speed and heavy load , Do not stop immediately, should gradually reduce the load and speed, and idling for 3-5 minutes, otherwise it will cause damage to the supercharger bearing and failure.


3. Regularly check the tightness and tightness of the pipes between the air filter and the supercharger, and the intake pipe between the supercharger and the engine, otherwise it will cause whistling.


4. Check the air filter according to the engine manual and clean or replace the filter element regularly.


5. Regularly remove the compressor casing and turbine casing, and clean the two impellers and the inner flow channels of the two casings. After the supercharger is disassembled, clean oil should be added to the oil inlet during assembly.


6. Special reminder: The supercharger rotor shaft is a precision high-speed rotating part, disassembly and collision are strictly prohibited, otherwise the factory guarantee will be invalid.


The above content is the introduction of the use and maintenance methods of the supercharger of the generator set organized by Dingbo Power Generation Equipment for reference. As a professional diesel generator manufacturer, we always insist on using first-class talents to build a first-class enterprise, create first-class products, create first-class services, and strive to build a first-class domestic enterprise. If you would like to get more information welcome to contact us via [email protected].

Share

Contact Us

  • Add.: No. 10 Kechuang Road, High tech Zone, Nanning, Guangxi, China
  • Tel.: +86 771 5805 269
  • Fax: +86 771 5805 259
  • Cellphone: +86 134 8102 4441
                    +86 138 7819 8542
  • E-mail: [email protected]
Follow Us

Copyright © Guangxi Dingbo Generator Set Manufacturing Co., Ltd. All Rights Reserved | Sitemap

Update cookies preferences

generator set:

Emergency vs Standby Generator: What’s The Difference? Commercial Generators Trailer Mounted Water Pumps for Sale
Contact Us