Home Products News Contact Us
Home > News > The Normal Operating Procedures of Volvo Diesel Generator Sets

The Normal Operating Procedures of Volvo Diesel Generator Sets

Aug. 04, 2023

Today we will give you a brief introduction about the normal operating procedures of Volvo diesel generator sets. If you have anything else you need to know, welcome to visit our Dingbo website, and then we will introduce the relevant content for you.


Volvo diesel generator 1000kw 1250kva Cummins Diesel Generator Set


Volvo diesel generator sets can run continuously under rated conditions. During operation, monitor and check that the following operating parameters do not exceed (or fall below) the specified value: voltage, current, cycle, power factor, lubricating oil, pressure, lubricating oil, temperature, cooling water, temperature, fuel tank oil Bit battery charging voltage. 400V±5% 2000A 50Hz 0.8 0.5MPa Need information 30~35℃ Normal 24V DC. The Volvo diesel generator set in operation should have no abnormal vibration, and the exhaust smoke of the Volvo diesel generator set should have no abnormal color. During normal operation, the Volvo diesel generator set operating mode selection switch is set to the "automatic" position.


The Volvo diesel generator set reaches the rated speed and rated voltage 10 seconds after starting. If the voltage of the guard bus returns to normal within 10 seconds, the outlet switch of the Volvo diesel generator set will not be closed; if the guard bus is still at low voltage, the Volvo diesel generator will automatically switch on The outlet switch of the unit provides power to the security bus. Diesel Volvo diesel generator sets are strictly prohibited from idling for a long time. If there is no load, it should be shut down for backup. The exhaust temperature in the exhaust pipe of Volvo diesel generator set is relatively high during operation. Therefore, it is strictly forbidden for people to approach the exhaust pipe to prevent burns, and ensure that there is no dirty oil or other flammable materials around the exhaust pipe to prevent fire.


After the Volvo diesel generator set is shut down, the coolant temperature is very high. At this time, it is strictly prohibited to open the radiator cover, and it is forbidden to fill the uncooled cooling system with coolant, otherwise it will cause serious damage to the diesel engine. After a Volvo diesel generator fails, it is strictly forbidden to restart it before troubleshooting and resetting. Volvo diesel generator set is in "manual" or "automatic" mode, and the fault has not been eliminated, it is strictly forbidden to press the fault reset button.


As a professional diesel generator manufacturer, we always insist on using first-class talents to build a first-class enterprise, create first-class products, create first-class services, and strive to build a first-class domestic enterprise. If you would like to get more information welcome to contact us via [email protected].

Share

Contact Us

  • Add.: No. 10 Kechuang Road, High tech Zone, Nanning, Guangxi, China
  • Tel.: +86 771 5805 269
  • Fax: +86 771 5805 259
  • Cellphone: +86 134 8102 4441
                    +86 138 7819 8542
  • E-mail: [email protected]
Follow Us

Copyright © Guangxi Dingbo Generator Set Manufacturing Co., Ltd. All Rights Reserved | Sitemap

Update cookies preferences

generator set:

Emergency vs Standby Generator: What’s The Difference? Commercial Generators Trailer Mounted Water Pumps for Sale
Contact Us