The Importance of Diesel Generator Oil Pressure

Aug. 04, 2023

The oil of the diesel generator set has a lubricating effect on the generator set, which can keep the diesel generator set in permanent operation. In addition to controlling the oil quality, here is a reminder that it is very important to properly control the generator oil pressure. Next, we will talk to you about the importance of oil pressure.


 500kw 625kva Perkins Diesel Generator Set


During the operation of the diesel engine, if the oil pressure is too low or too high, it will affect the lubrication quality of the diesel engine. Therefore, the oil pressure must be controlled within the specified range. The oil pressure range of the 135 series naturally aspirated diesel engine should be 0.25~0.35MPa, and the oil pressure range of the Deutz FL513 diesel engine should be 0.36~0.48MPa. Just 1 minute after the diesel engine is started, if the indication of the oil pressure gauge does not rise, it should be shut down quickly for inspection, the cause has been found and the fault has been eliminated, and then the engine should be started and the oil pressure should be observed.


When the diesel engine is running from low speed to high speed, the oil pressure gradually increases. After the diesel engine reaches the rated speed, the oil pressure slowly returns to the specified value. If the specified value cannot be restored within 15 minutes, the oil pressure must be adjusted. Diesel engines have a pressure regulating valve on the side of the oil filter. Remove the nut, loosen the nut, and turn the adjusting bolt with a screwdriver.


When the bolt is screwed in, the oil pressure should increase; when the bolt is screwed out, the oil pressure should decrease. After adjustment, tighten the lock nut. If the oil pressure is still too low after adjusting the oil pressure, the quality of the diesel oil suction pan or the oil should be checked. In the actual application process of diesel generator set, you can control the appropriate oil pressure according to the specific situation. For details, you can refer to the above adjustment method to ensure the normal operation of the diesel engine, so as to ensure the operation of the diesel generator set.


Dingbo Power was founded in 2006 and is one of the earliest manufacturers of generators and diesel generator sets in China. If you want get more information, please feel free to send email to [email protected] we will pay highly attention on your question.

Share

Contact Us

  • Add.: No. 10 Kechuang Road, High tech Zone, Nanning, Guangxi, China
  • Tel.: +86 771 5805 269
  • Fax: +86 771 5805 259
  • Cellphone: +86 134 8102 4441
                    +86 138 7819 8542
  • E-mail: [email protected]
Follow Us

Copyright © Guangxi Dingbo Generator Set Manufacturing Co., Ltd. All Rights Reserved | Sitemap

Update cookies preferences

generator set:

Emergency vs Standby Generator: What’s The Difference? Commercial Generators Trailer Mounted Water Pumps for Sale
Contact Us