The control panel of Cummins diesel generator is divided into ordinary Cummins diesel generator control panel and automatic Cummins diesel generator control panel. So what functions does it have?  As a Cummins diesel generator manufacturer, we will show you the details.

60kw/ 50kw volvo perkins Diesel Generator Set

The ordinary Cummins diesel generator control panel is the most basic configuration to meet the normal operation and use of the unit. It has the advantages of simple operation, complete functions, and reliable protection. The panel has operation buttons such as power-on, preheating, starting, and stopping (emergency stop). When a fault alarm occurs, the control panel will send out a corresponding fault light (sound) alarm while controlling the Cummins diesel generator to stop.


The ordinary unit control panel is composed of circuit breaker, ammeter, voltmeter, frequency meter, water temperature meter, oil pressure meter, oil temperature meter, tachometer, timer and current transformer. It can complete the start and stop of Cummins diesel generator. Control functions such as power supply and power failure, and measure, display, alarm and protect the running status of Cummins diesel generators.


The automatic Cummins diesel generator control panel is suitable for the control of automated Cummins diesel generators. Cummins diesel generators can be started and stopped, power supply and power-off, status adjustment, etc., can be done manually or automatically.


The automatic Cummins diesel generator control panel is composed of automatic controllers, automatic heaters, automatic charger automatic switching devices, circuit breakers, ammeters, voltmeters, charging current meters, DC voltmeters, voltage frequency meters, water temperature meters, oil pressure meters, and oil Thermometer, diesel engine tachometer, timer, alarm buzzer, control relay, protection switch and circuit transformer, etc. The automatic Cummins diesel generator control panel can automatically complete the control functions of starting and stopping the unit, power supply and power failure, and test, display, over-limit alarm and protection of the unit's operating status.


Dingbo Power was founded in 2006 and is one of the earliest manufacturers of generators and diesel generator sets in China. If you want get more information, welcome send email to [email protected] we will pay highly attention on your question.

Share

Contact Us

  • Add.: No. 10 Kechuang Road, High tech Zone, Nanning, Guangxi, China
  • Tel.: +86 771 5805 269
  • Fax: +86 771 5805 259
  • Cellphone: +86 134 8102 4441
                    +86 138 7819 8542
  • E-mail: [email protected]
Follow Us

Copyright © Guangxi Dingbo Generator Set Manufacturing Co., Ltd. All Rights Reserved | Sitemap

Update cookies preferences

generator set:

Emergency vs Standby Generator: What’s The Difference? Commercial Generators Trailer Mounted Water Pumps for Sale
Contact Us