We believe that many customers of diesel generator sets will notice that a small air hole is left on the cover of the fuel tank of diesel generator sets. Why is this? Leave a small air hole in the fuel tank not only is easy to enter air, moisture and dust, but also the fuel is easy to volatilize and overflow. Then why leave such a small air hole? This naturally makes sense. These pores are directly related to the normal use of diesel generator sets, and are also necessary for the performance of diesel generator sets. We will explain the scientific reasoning here.


80kw 100kva Cummins Diesel Generator Set


1. In order to prevent the fuel in the fuel tank from spilling out due to vibration, as well as the overflow of oil vapor and the ingress of external dust, the fuel tank should be covered and sealed. However, when the fuel level drops due to fuel consumption, a certain degree of vacuum will be formed in the fuel tank, which will cause the fuel pump to lose its ability to absorb fuel.


2. When the temperature is high, the fuel will evaporate, and the fuel vapor will make the pressure in the fuel tank too high. In both cases, it is required to automatically communicate with the atmosphere when there is a pressure difference between the inside and outside of the fuel tank. Therefore, a vent hole should be provided on the cover of the fuel tank to balance the air pressure inside and on the surface of the fuel tank.


3. Make sure that the vent hole on the fuel tank cover is smooth when using it. If the vent is blocked or the fuel tank port is pierced with a plastic sheet after the fuel tank cap is lost, then when the diesel generator set is working, the fuel tank will have a negative pressure due to the drop of the fuel level, and the diesel generator set will not work. Phenomena such as stability, power drop, automatic flameout, and difficulty to start in the warm state.


From the above introduction, I believe everyone already knows that although the pores are a small design, they play a very large role. Therefore, when you use diesel generator sets, you should always pay attention to the status of the pores and pay attention to the existence of pores. There is no blockage to ensure the working efficiency of the diesel generator set.


Dingbo Power was founded in 2006 and is one of the earliest manufacturers of generators and diesel generator sets in China. If you want get more information, welcome send email to [email protected] we will pay highly attention on your question.

Share

Contact Us

  • Add.: No. 10 Kechuang Road, High tech Zone, Nanning, Guangxi, China
  • Tel.: +86 771 5805 269
  • Fax: +86 771 5805 259
  • Cellphone: +86 134 8102 4441
                    +86 138 7819 8542
  • E-mail: [email protected]
Follow Us

Copyright © Guangxi Dingbo Generator Set Manufacturing Co., Ltd. All Rights Reserved | Sitemap

Update cookies preferences

generator set:

Emergency vs Standby Generator: What’s The Difference? Commercial Generators Trailer Mounted Water Pumps for Sale
Contact Us