Home Products News Contact Us
Home > News

Starlight Power Sold 4 units Generator Set Powered by Cummins Engine

Jun. 13, 2020

On June 8, 2020, we sold 4 units diesel generator set powered by Cummins engine. They are 2 units 1000kw, 1 unit 150kw and 1 unit 120kw. The 4 units are powered for motorway project. The total investment of the motorway project is 36.84 billion yuan, with a total length of 162.3 km and a design speed of 100 km/h. The buyer is very satisfied with our product and service, so they purchased genset from us again, this is the fourth cooperation.


Our Cummins diesel generator set is the most popular among Perkins, Volvo, Deutz, Yuchai, Shangchai, Ricardo etc, because of low fuel consumption, stable performance and high quality tec.

 

Below are the technical specifications of 1000kw, 150kw and 120kw Cummins diesel generators.

1. 1000KW Cummins diesel genset

Prime/standby: 1000kw/1100kw

Genset type: open type

Rated current: 1800A

Rated voltage: 230/400V

Speed/frequency: 1500rpm/50Hz

Power factor: 0.8lag

Diesel engine: Cummins/ QSK38-G5

Alternator: Shanghai Kepu/ TFW2-1000

Controller: SmartGen HGM6110

Overall size: 4800x 2080x2350mm

Net weight: 9800kg


1000kw Cummins genset


2. 150kw Cummins power diesel generator

Prime/standby: 150kw/165kw

Genset type: open type

Rated current: 270A

Rated voltage: 230/400V

Speed/frequency: 1500rpm/50Hz

Power factor: 0.8lag

Diesel engine: Cummins/ QSB6.7-G4

Alternator: Shanghai Kepu/ TFW2-150

Controller: SmartGen HGM6110

Overall size: 2400x 850x1500mm

Net weight: 1700kg

3. 120KW Cummins electric generator

Prime/standby: 120kw/132kw

Genset type: open type

Rated current: 216A

Rated voltage: 230/400V

Speed/frequency: 1500rpm/50Hz

Power factor: 0.8lag

Diesel engine: Cummins/ 6BTAA5.9-G12

Alternator: Shanghai Kepu/ TFW2-120

Controller: SmartGen HGM6110

Overall size: 2300x 830x1400mm

Net weight: 1300kg

 

Accessories of about genset are included auto start/stop monitoring system, silencer, battery charger, 24V DC battery, rubber shock pad, factory test, operation manual, maintenance and repair manual etc. For 1000kw Cummins genset, also includes one set of maintenance tool kit.

 

Advantages of Starlight diesel generators with Cummins engine

1. Low oil consumption, stable and reliable performance, simple and convenient maintenance, long service life.

2. Advanced technologies for fuel system, control system, air intake treatment, filtration system, exhaust gas treatment system and power system. So its performance is very good.

3. The main design features of Cummins engine are solid and durable cylinder body, low vibration and noise.  In-line six cylinder four stroke, stable operation and high efficiency; replacement of wet cylinder sleeve, two cylinders and one cover, four valves per cylinder, sufficient air intake, forced water cooling, small thermal radiation and excellent performance.

4. Excellent quality, low noise, small volume, strong output power, reliable performance. 

5. Global warranty.


We are a manufacturer of electric generators in China, our Cummins genset power range is from 20kw to 2000kw, if you have purchase plan, welcome to contact us by email sales@dieselgeneratortech.com or call us +8613481024441.

Share
Contact Us
  • Adds: No.2 Xingguang Road, Guxi Industrial Park, Taixing, Jiangsu, China.
  • Tel: +86 771 5805 269
  • FAX: +86 771 5805 259
  • Cellphone: +86 134 8102 4441
                    +86 138 7819 8542
  • E-mail: sales@dieselgeneratortech.com
Follow Us

Copyright © Jiangsu Starlight Electricity Equipments Co., Ltd.All Rights Reserved | Sitemap

Contact Us