Home Products News Contact Us
Home > News

Starlight Generator Winter Maintenance Announcement

Apr. 07, 2023

In recent years, the temperature is getting colder and colder, so winter maintenance of diesel generator sets needs to be put on an important agenda. The following are some precautions and related measures for Starlight Power's winter maintenance of the unit:

 

1. After the diesel generator set operates in winter, if it is parked in the open, the weather change shall be noticed at any time. When the local temperature is lower than 5 ℃, the cooling water in the diesel engine cooling water tank shall be discharged. Because the volume change of water is relatively large when the temperature is below 5 degrees Celsius, when water changes from liquid to solid, the volume expansion will damage the cooling water tank radiator.

 

2. Due to the poor working environment of the generator set in winter, it is necessary to frequently replace the air filter element. Due to the high requirements for air and diesel filter elements in cold weather, if not replaced in a timely manner, it will increase engine wear and affect the lifespan of the diesel engine.

 

diesel generator set


3. When selecting engine oil for winter diesel engines, it is advisable to choose oil with a slightly thinner viscosity.

 

4. When a diesel engine is started in winter, the temperature of the intake air in the cylinder is relatively low, making it difficult for the piston to reach the natural temperature of the diesel after compressing the gas. So before starting the diesel engine, corresponding auxiliary methods should be used to increase the temperature of the diesel engine body.

 

5. After starting the diesel engine, it should first run at low speed for 3-5 minutes to increase the overall temperature of the diesel engine, check the working condition of the lubricating oil, and only after checking it to be normal can it be put into normal operation. During the operation of a diesel engine, try to minimize sudden acceleration or maximum throttle operation, otherwise prolonged operation may affect the service life of the valve components.

 

Jiangsu Starlight Electricity Equipments Co.,Ltd. is a professional manufacturer of generators, diesel generator sets, Shangchai generator sets, Volvo generator sets, etc. It has 64 sales and service departments, and provides users with one-stop service of design, supply, debugging and maintenance at any time. Welcome the majority of users call for consultation. For more details, please contact us with sales@dieselgeneratortech.com.


Share
Contact Us
  • Adds: No.2 Xingguang Road, Guxi Industrial Park, Taixing, Jiangsu, China.
  • Tel: +86 771 5805 269
  • FAX: +86 771 5805 259
  • Cellphone: +86 134 8102 4441
                    +86 138 7819 8542
  • E-mail: sales@dieselgeneratortech.com
Follow Us

Copyright © Jiangsu Starlight Electricity Equipments Co., Ltd.All Rights Reserved | Sitemap

Contact Us