Now that industrial power consumption continues to increase, there is no way to power outages. Power outages can disrupt the production costs of enterprises and can constitute an interruption of industrial processes that have a major impact. Whether it is a few seconds or a few hours, the impact can be large. Due to the ability to provide continuous, high-efficiency power (up to 1500 kilowatts) in any emergency situation, industrial diesel generator sets will meet every challenge. For greater power requirements, industrial diesel generator sets can be paralleled.


Generac 24kW Standby Generator System (200A Service Disc. + AC Shedding) w/ WiGenerac / Wi-Fi


After an interruption, other fuel sources may take up to two minutes or more. This time it is a more efficient industrial diesel generator set that provides power faster and more costly than other fuel sources. This is why industrial diesel generator sets are the most reliable source of backup power on the market today.


The steps to remove the oil seal of a diesel generator set are as follows:


(1) Heat the diesel to 45℃~56℃ above to wash and wipe off the external anti-rust oil.


(2) Heat the water above 90°C, and then continuously pour it in from the water outlet of the water jacket, and it will flow out from the drain switch (or water pump inlet) on the side of the cylinder block. Continue for 2-3 hours, and shake the crankshaft intermittently. , So that the rust-preventing oil on the surface of the piston top, cylinder liner and other places will dissolve and flow out.


(3) Clean the oil pan with clean diesel oil and replace with new engine oil. The cooling and fuel system, fuel injection speed control system, water pump, and starting transmission system should be cleaned and inspected according to the instructions, and sufficient clean cooling water should be added, sufficient starting batteries, and preparations before starting up.


Dingbo Power was founded in 2006 and is one of the earliest manufacturers of generators and diesel generator sets in China. If you want get more information, please feel free to send email to [email protected] we will pay highly attention on your question.

Share

Contact Us

  • Add.: No. 10 Kechuang Road, High tech Zone, Nanning, Guangxi, China
  • Tel.: +86 771 5805 269
  • Fax: +86 771 5805 259
  • Cellphone: +86 134 8102 4441
                    +86 138 7819 8542
  • E-mail: [email protected]
Follow Us

Copyright © Guangxi Dingbo Generator Set Manufacturing Co., Ltd. All Rights Reserved | Sitemap

Update cookies preferences

generator set:

Emergency vs Standby Generator: What’s The Difference? Commercial Generators Trailer Mounted Water Pumps for Sale
Contact Us