How to put the water tank of the generator set? Dingbo power generation equipment believes that because the external ambient temperature is too low, the cooling water should be discharged after 15 minutes of shutdown when the water temperature drops, not immediately, otherwise the generator set will be caused by the excessive temperature difference between the fuselage and the external environment. Some parts of the generator are deformed, which in turn affects the performance of the generator set (such as cylinder head deformation and other issues).


deutz hatz cummins perkins volvo


When the cooling water stops flowing out, it is best to shake the generator set for a few more turns. At this time, the remaining cooling water that is not easy to flow out will flow out due to the vibration of the generator set, so as to prevent the water block on the cylinder head from being frozen. fall, the cooling water will flow into the oil casing in the future. The operator should also note that if the water discharge switch is not removed, the water discharge switch should be turned on after the water discharge is completed to prevent the remaining cooling water from being temporarily unable to flow out due to various reasons and freezing the corresponding parts of the generator set cause unnecessary losses.


Dingbo power generation equipment reminds users not to turn on the water discharge switch when water is discharged, and everything will be fine. They should also pay attention to observe the specific conditions of the water flow to see whether the water flow is smooth, and whether there is a phenomenon that the water flow becomes smaller or faster or slower. If these situations occur, it means that the cooling water contains impurities, which hinder the normal outflow of water. At this time, it is best to remove the drain switch and let the cooling water flow directly from the body. If the water flow is still not smooth, then use a hard and slender steel object such as iron wire to dredge until the water flow is smooth.


Dingbo Power was founded in 2006 and is one of the earliest manufacturers of generators and diesel generator sets in China. If you want get more information, please feel free to send email to [email protected] we will pay highly attention on your question.

Share

Contact Us

  • Add.: No. 10 Kechuang Road, High tech Zone, Nanning, Guangxi, China
  • Tel.: +86 771 5805 269
  • Fax: +86 771 5805 259
  • Cellphone: +86 134 8102 4441
                    +86 138 7819 8542
  • E-mail: [email protected]
Follow Us

Copyright © Guangxi Dingbo Generator Set Manufacturing Co., Ltd. All Rights Reserved | Sitemap

Update cookies preferences

generator set:

Emergency vs Standby Generator: What’s The Difference? Commercial Generators Trailer Mounted Water Pumps for Sale
Contact Us