Home > News > How to Clean the Filter of Volvo Diesel Generator Set?

How to Clean the Filter of Volvo Diesel Generator Set?

Aug. 05, 2023

When Volvo diesel generator sets are used in different seasons, the crankcase and lubrication surfaces should be cleaned. Used mixing engine oil, kerosene and diesel as washing oil. Washing oil can be added after the engine oil is discharged for cleaning. Then, the Volvo diesel generator set runs at low speed 3- After 5 minutes, drain the washing oil and add new engine oil.


Perkins generator 100kw 2250kva Cummins Diesel Generator Set


The various fuel filters in the fuel supply system should be cleaned of debris once every 100-200 hours of work, and the fuel tank and various fuel pipelines should be thoroughly cleaned. When cleaning the filter element and seals, you should be especially careful, and if they are damaged, they need to be replaced in time. When changing the oil during the seasonal transition, all parts of the entire fuel supply system should be cleaned. The diesel used should meet the seasonal requirements and undergo a 48-hour sedimentation purification treatment.


(1) To connect two units in parallel, first adjust the no-load voltage and voltage regulation characteristics of the two units to be exactly the same. This is a prerequisite to ensure the complete and even distribution of the reactive power of the two units, and it is also the subsequent adjustment of the two units. The basis for the equal distribution of power. Only after the above two adjustments and balances can it be ensured that the output voltages of the two units operating in parallel are equal under any load, and at the same time the power is equally distributed, so as to ensure that the circulating current is 0 (ideal state). It shows that the root cause of circulating current is that the no-load voltages of the two units are not completely equal or the voltage regulation characteristics are different, resulting in unequal output voltages and circulating currents.


(2) The no-load voltage and voltage regulation characteristics of the two units are equal, and the output currents of the two units are not equal, that is, the power distribution of the two units is uneven, which will also cause U1 and U2 to be unequal, resulting in circulating current.


(3) There are many factors that affect the distribution of reactive power, such as the characteristics of automatic voltage regulators and the stabilizing effect of the voltage equalizing link, which will not be analyzed here.


Check the fuel filter element, if it is clogged or there are a lot of impurities, please replace the fuel filter; check the fuel supply pipeline, if there is any leakage, deal with it to prevent air from entering the fuel supply pipeline when the engine is running; check the air Use compressed air to clean or replace the filter element of the filter element; measure the fuel temperature, if the fuel temperature exceeds 50℃, please cool down the fuel or add fuel to reduce its temperature; check the engine exhaust pipe to ensure that the exhaust pipe reaches Smooth, ensure that the exhaust pressure is less than 90mmhg; in the cold state or after 5-10 minutes of shutdown, check the oil level of the oil pan with a dipstick. If the oil level has exceeded the "H" level, please drain the excess oil It is advisable to keep the liquid level between the "L" and "H" positions close to the "H" position; in the running state, check the air pipe between the rear end of the turbocharger and the intake manifold with the necessary tools ( Pay attention to prevent burns caused by high-temperature and high-pressure gas), and tighten the leaking parts.


As a professional diesel generator manufacturer, we always insist on using first-class talents to build a first-class enterprise, create first-class products, create first-class services, and strive to build a first-class domestic enterprise. If you would like to get more information welcome to contact us via sales@dieselgeneratortech.com.

Share
Contact Us
  • Add.: Room 601, Laboratory Building, No.2 Gaohua Road, Nanning, Guangxi, China.
  • Tel.: +86 771 5805 269
  • Fax: +86 771 5805 259
  • Cellphone: +86 134 8102 4441
                    +86 138 7819 8542
  • E-mail: sales@dieselgeneratortech.com
Follow Us

Copyright © Guangxi Dingbo Power Equipment Manufacturing Co., Ltd. All Rights Reserved | Sitemap

Update cookies preferences

seokeywords:

test2
Contact Us