Home Products News Contact Us
Home > News > Export 20KW 50KW Small Weichai Generator Set to Venezuela

Export 20KW 50KW Small Weichai Generator Set to Venezuela

Aug. 07, 2023

Recently, Dingbo Power exports 20KW and 50KW Weichai generator set to Venezuela. They are open type generator set with ATS for emergency use. The customer's location is often blackout, these gensets will bring the customer electricity security.

 

Dingbo Power is the OEM supplier of Weichai engine for diesel generator set. The Weichai generators mentioned above is produced by Dingbo Power. Weichai has always adhered to the operation strategy of product-driven and capital-driven, and is committed to developing products with three core competitiveness: quality, technology and cost. Dingbo Power also always focuses on good quality and competitive price diesel generators to promote the good development of electric power industry.

 

Main configurations of 20kw, 50kw diesel generator set are as follows:

20KW:

Speed 1800rpm, frequency 60Hz, voltage 127/220V, 3 phase 4 wire, power factor 0.8lag. Insulation class H, with radiator, driven by Fan with safety guard. 12V DC electric start.

 

Diesel engine brand/model: Weichai / WP2.3D30E201 (4 cylinder, inline, 4 stroke, naturally-aspirated, water-cooled)

Alternator brand/ model: Shanghai Kepu /TFW2-20 (brushless self excitation)

Controller brand/model: SmartGen/ HGM6110N (automatic controller, LCD display).

Automatic transfer switch ( ATS)

Steady governing rate: ≤ 5%

Fuel consumption at rated working condition:  ≤208g/kW·h±3%

Spare parts: Oil filter, fuel filter, air filter


weichai diesel generator 80KW 100KVA CUMMINS Diesel Generator Set


 

50KW:

Speed 1800rpm, frequency 60Hz, voltage 127/220V, 3 phase 4 wire, power factor 0.8lag. Insulation class H, with radiator, driven by Fan with safety guard. 12V DC electric start.


Diesel engine brand/model: Weichai / WP2.3D58E201(4 cylinder, inline, 4 stroke, turbocharged & intercooled, water-cooled)

Alternator brand/ model: Shanghai Kepu /TFW2-50(brushless self excitation)

Controller brand/model: SmartGen/ HGM6110N ( automatic controller, LCD display).

Automatic transfer switch ( ATS)

Steady governing rate: ≤ 5%

Fuel consumption at rated working condition:  ≤208g/kW·h±3%

Spare parts: Oil filter, fuel filter, air filter 

Dingbo Power can produce 20kw~2750kw diesel generator set with Weichai engine, frequency 50Hz/60Hz can be selected. Welcome to call us +8613481024441 to get more information.

 

Here are some recommendation for diesel generator maintenance.

1.Check oil and water level, air filter every day.

2.Check start-up battery and V type belt tension after 250 running hours or 3 months.

3.Change oil and oil filter after 250 running hours or 3 months.

 

The maintenance period of diesel generator set shall be calculated according to working hours and calendar time, whichever comes first.

 

According to the actual operation condition of Weichai generators, the customer shall carry out maintenance in advance if necessary. The maintenance cycle and maintenance items of the engine should be adjusted according to the use, service condition and the performance of fuel and lubricating oil.

 

The standby diesel generator set is required to maintain a good standby state of rapid start-up and operation, so it is required to carry out regular maintenance and the following commissioning:

1. Run for 5-10 minutes with proper load every week;

2. Run for 5-30 minutes with proper load every month;

3. Check starting performance, lubricating oil pressure, exhaust smoke color, vibration etc.

Share

Contact Us

  • Add.: No. 10 Kechuang Road, High tech Zone, Nanning, Guangxi, China
  • Tel.: +86 771 5805 269
  • Fax: +86 771 5805 259
  • Cellphone: +86 134 8102 4441
                    +86 138 7819 8542
  • E-mail: [email protected]
Follow Us

Copyright © Guangxi Dingbo Generator Set Manufacturing Co., Ltd. All Rights Reserved | Sitemap

Update cookies preferences

generator set:

Emergency vs Standby Generator: What’s The Difference? Commercial Generators Trailer Mounted Water Pumps for Sale
Contact Us