Oct. 09, 2025

A valued client from the Middle East ordered a sophisticated high-power open type diesel generator set from Dingbo Power in July 2025. This genset delivers 1250kVA prime power output that is reliable and versatile. It is easy to maintain and suitable for a variety of applications such as heavy duty construction.   


Technical data of 1250kVA diesel generator set

 

Manufacturer: Guangxi Dingbo Power Equipment Manufacturing Co.,Ltd

Genset model: DB-1000GF

Type : Open type

Prime Rating Power: 1250KVA/ 1000KW

Standby Rating Power: 1375KVA/ 1100KW

Rated current: 1800A

Rated voltage: 400/230V

Rated speed/frequency: 1500rpm/50Hz

Power factor: 0.8lag

Phase: 3 phase 4 wire

Diesel engine: Cummins KTA50-G3

Alternator: Genuine Stamford S6L1D-H41

Controller: Deep Sea DSE8610MKII


 

Dingbo Power Exported 1250kVA Cummins Diesel Generator to the Middle East


Engine specifications


Manufacturer:Chongqing Cummins Engine Co.,Ltd
Engine modelKTA50-G3
Prime/Standby power:1097KW/1227KW
Frequency/Speed:50Hz/1500RPM
Cylinders no. & Type:16 cylinders, V-type, 4 stroke, diesel engine, water-cooled with radiator with fan
Aspiration:Turbocharged and Aftercooled
Displacement:50.3L
Compression ratio13.9:1
Governor:Electronic speed control
Bore x Stroke(mm):159 x 159
Start mode:Electric start
Starter motor:24V DC, negative ground
Fuel System:Direct Injection Cummins PT
Fuel consumption

Standby power@100%: 293L/hr

Prime power@100%: 261 L/hr

Prime power@75%: 199 L/hr 

Prime power@50%:139 L/hr 

Prime power@25%: 76 L/hr

Total Lubrication System Capacity (Including Bypass Filter)177L
Cooling wayWater-cooled
Coolant capacity- engine only161L


This Cummins generator set is configured as a complete power package, featuring a sizable 1200-liter base fuel tank for extended operation, along with oil and water jacket heaters to ensure reliable starting and optimal performance in varying climatic conditions. A comprehensive suite of sensors monitors all critical parameters, including engine temperature, oil pressure, coolant temperature, frequency, current, voltage, speed, fuel level, and cooling system status, ensuring full operational awareness.

 

A key feature of this genset, as specified by the client, is the integration of a specialized Over/Under Voltage Shunt Relay. This system is designed for enhanced protection in a parallel operation scenario with the client's existing gensets. In the event of an over-voltage or under-voltage condition (often indicative of an overload), the relay will act to disconnect the load via the frame circuit breaker. Crucially, the generator set itself is configured to register an alarm but continue running without an immediate, abrupt shutdown. The subsequent shutdown command is then managed gracefully by the DSE8610MKII controller, initiating a smooth and controlled shutdown sequence.

 

This soft shutdown approach is critical for protecting the generator set from potential damage caused by sudden stops and ensures greater stability within the client's parallel power system.

 

We are confident that this highly customized 1250kVA generator set will deliver reliable, intelligent, and stable power, meeting the client’s operational needs precisely. This order reinforces our position as a trusted provider of high-quality power generation solutions for the international market.

 

If you are looking for a brand new diesel generator for your project, feel free to contact Dingbo Power today.


Share

Contact Us

  • Add.: No. 10 Kechuang Road, High tech Zone, Nanning, Guangxi, China
  • Tel.: +86 771 5805 269
  • Fax: +86 771 5805 259
  • Cellphone: +86 134 8102 4441
                    +86 138 7819 8542
  • E-mail: [email protected]
Follow Us

Copyright © Guangxi Dingbo Generator Set Manufacturing Co., Ltd. All Rights Reserved | Sitemap

Update cookies preferences

generator set:

Emergency vs Standby Generator: What’s The Difference? Commercial Generators Trailer Mounted Water Pumps for Sale
Contact Us