Aug. 03, 2023

The performance of diesel generator set is closely related to diesel combustion. Diesel generator set obtains generator power through diesel combustion, thereby generating electricity to meet the normal demand for power supply. Therefore, the performance of diesel generator set is closely related to diesel combustion. The high diesel combustion consumption rate to help units or enterprises using diesel generator sets to reduce power generation costs has become a concern of customers.


deutz hatz cummins perkins volvo generator


The way to improve the fuel consumption rate is to adjust the fuel supply system of the unit. That is, after the diesel generator set works normally for 400 hours or the fuel injection pump-speed governor assembly. Correct the fuel supply advance angle when reassembling. The adjustment method of the fuel supply advance angle is as follows:


Remove the high-pressure oil pipe of the first cylinder of the fuel injection pump-speed governor assembly, and lock the handle on the governor at the rated fuel supply position of the diesel generator set.


Next, turn the flywheel according to the running direction of the diesel generator set, observe the fuel supply of the first cylinder of the fuel injection pump during the rotation, and stop rotating the crankshaft when the oil level of the first cylinder is just fluctuating.


If the degree of fuel supply on the flywheel corresponding to the pointer on the flywheel housing does not match the specified fuel supply angle of this type of diesel engine, loosen the two locking screws on the combination plate of the fuel injection pump, and then turn the crankshaft so that the pointer aligns with the specified oil supply angle. The angle within the range, tighten the two fixing screws.


After adjusting the oil supply system of the diesel generator set, the diesel combustion consumption rate can be guaranteed to be rated, which not only improves the performance of the diesel generator set, but also saves the cost for the customer.


As a professional diesel generator manufacturer, we always insist on using first-class talents to build a first-class enterprise, create first-class products, create first-class services, and strive to build a first-class domestic enterprise. If you would like to get more information welcome to contact us via [email protected].

Share

Contact Us

  • Add.: No. 10 Kechuang Road, High tech Zone, Nanning, Guangxi, China
  • Tel.: +86 771 5805 269
  • Fax: +86 771 5805 259
  • Cellphone: +86 134 8102 4441
                    +86 138 7819 8542
  • E-mail: [email protected]
Follow Us

Copyright © Guangxi Dingbo Generator Set Manufacturing Co., Ltd. All Rights Reserved | Sitemap

Update cookies preferences

generator set:

Emergency vs Standby Generator: What’s The Difference? Commercial Generators Trailer Mounted Water Pumps for Sale
Contact Us