Cummins diesel generator set adopts water cooling method, and the cooling water circulation system includes water tank, water pipe, fan, radiator, water pump and temperature controller. After a Cummins diesel generator set has been used for a period of time, it is necessary to maintain the radiator fan. The main maintenance items include: check whether the fan has cracks. If cracks are found, it needs to be replaced or repaired in time.


80kw 100kva Cummins Diesel Generator Set


Check whether the fan blades of the Cummins diesel generator set are loose. If they are loose, they can be repaired by heavy riveting blades; if the inclination angle of the fan blades is not correct (the inclination angle of each blade should be normally 40°-45°), it needs to be corrected by cold pressing .


Inspection of the fan maintenance of Cummins diesel generator set: After the fan is repaired, in order to ensure the smooth operation of the fan, a static balance test is required. The method is as follows: fix the blade and the frame under the special purpose, and put it on the iron for inspection. When checking, gently move the blade by hand to make the impeller with shaft rotate on the shaped iron. After it stops automatically, mark the lower impeller. Repeat this several times. If the same blade is located in the lower position each time, it means that the blade is relatively heavier than the other blades. Use a grinding wheel to grind off a little metal on its end or rear side to achieve static balance.


As a professional diesel generator manufacturer, we always insist on using first-class talents to build a first-class enterprise, create first-class products, create first-class services, and strive to build a first-class domestic enterprise. If you would like to get more information welcome to contact us via [email protected].

Share

Contact Us

  • Add.: No. 10 Kechuang Road, High tech Zone, Nanning, Guangxi, China
  • Tel.: +86 771 5805 269
  • Fax: +86 771 5805 259
  • Cellphone: +86 134 8102 4441
                    +86 138 7819 8542
  • E-mail: [email protected]
Follow Us

Copyright © Guangxi Dingbo Generator Set Manufacturing Co., Ltd. All Rights Reserved | Sitemap

Update cookies preferences

generator set:

Emergency vs Standby Generator: What’s The Difference? Commercial Generators Trailer Mounted Water Pumps for Sale
Contact Us