Home Products News Contact Us
Home > News > Correct Management Method of Diesel Engine Cooling System in Winter

Correct Management Method of Diesel Engine Cooling System in Winter

Aug. 03, 2023

Today, we will briefly introduce to you how to correctly use the generator oil radiator and the correct management method of the diesel engine cooling system in winter.


For new generators, if the oil cooling method is water-cooled, the generator should be in an idle state when starting, and the working condition of the oil radiator should be checked. If it is good, the speed can be increased. After the diesel engine is stopped, the cooling water in the oil radiator must be drained in winter, otherwise the oil radiator will be damaged. When using the generator in winter, the diesel engine body must be leveled, otherwise even if the drain valve of the oil radiator is opened, the water may not be able to be drained completely. If a small amount of cooling water remains in the oil radiator, the oil will be dissipated. The thin tube of the device was frozen.


deutz hatz cummins perkins volvo generator


When conditions permit, antifreeze should be added to the cooling water radiator in winter. When conditions do not allow, hot water can also be added to the cooling water radiator after the generator is started. After the generator is started, add cold water to the cooling water radiator, but the body drain valve and the water valve of the radiator must be opened until the cooling water flows out of the body drain valve, then close the drain valve and continue to the cooling water radiator Add cold water until it is full. If the drain valve of the generator body and the cooling water radiator is not opened, the cooling water cannot all enter the body due to the hot air pressure generated by the body. In severe cases, the cooling water may freeze in the cooling water. In the water radiator, the phenomenon of boiling occurs.


After the shutdown, the cooling water should be drained. If it is difficult to drain the cooling water, the generator can also be started at this time, and the cooling water can be drained by the hot air pressure generated inside the body. Remember, don't forget the oil cooler when waterproofing And the two drain valves of the body to prevent the oil cooler and the body from freezing and cracking.


Dingbo Power was founded in 2006 and is one of the earliest manufacturers of generators and diesel generator sets in China. If you want get more information, please feel free to send email to [email protected] we will pay highly attention on your question.

Share

Contact Us

  • Add.: No. 10 Kechuang Road, High tech Zone, Nanning, Guangxi, China
  • Tel.: +86 771 5805 269
  • Fax: +86 771 5805 259
  • Cellphone: +86 134 8102 4441
                    +86 138 7819 8542
  • E-mail: [email protected]
Follow Us

Copyright © Guangxi Dingbo Generator Set Manufacturing Co., Ltd. All Rights Reserved | Sitemap

Update cookies preferences

generator set:

Emergency vs Standby Generator: What’s The Difference? Commercial Generators Trailer Mounted Water Pumps for Sale
Contact Us