Home Products News Contact Us
Home > News > Correct Maintenance Operation of Diesel Generator Accessories

Correct Maintenance Operation of Diesel Generator Accessories

Aug. 05, 2023

The correct maintenance of diesel generator parts is a necessary condition to ensure the safe operation of diesel generators, and it is also a necessary condition to reduce diesel generator failures. It is also a skillful subject for the operator to properly maintain the performance of diesel generator accessories.


Diesel generator parts need to be kept clean: such as the fuel filter, oil filter, air filter, hydraulic oil filter and various filters of diesel generators, if they are too dirty, they will Lead to poor filtering effect. Dirty parts such as water tank heat sink, air-cooled engine block and cylinder head heat sink, and cooler heat sink will cause poor heat dissipation and excessive temperature.


Some parts are afraid of heat and too high temperature: the piston temperature of Yuchai diesel engine is too high, which will easily lead to overheating and melting, resulting in cylinder holding. Overheating of rubber seals, triangular tapes, tires, etc., is prone to premature aging, performance degradation, and shortened service life. The coils of electrical equipment such as starters, alternators, regulators, etc. are overheated, and are easily burned and scrapped.


Perkins generator 100kw 2250kva Cummins Diesel Generator Set


Missing parts are likely to leave hidden troubles: Yuchai diesel engine valve locks should be installed in pairs, such as missing or missing. It will cause the valve to lose control and damage the piston and other parts. Anti-loosening devices such as engine connecting rod bolts, flywheel bolts, drive shaft bolts, cotter pins, locking screws, fuse plates or spring washers, if they are not installed, may cause serious malfunctions of diesel power generation and diesel generators during use. happen. If the oil nozzle used to lubricate the gears in the engine timing gear chamber is missing, it will cause serious oil leakage there.


It is strictly forbidden to install the gasket of important parts in reverse: the engine cylinder head gasket cannot be installed in reverse, otherwise it will cause premature ablation and damage of the gasket. When installing the engine fan blades, do not reverse it. For tires with directional patterns and herringbone pattern tires, the ground impression after installation should make the chevron tip point to the rear. Once these components are installed reversely, unnecessary failures may occur.


The above is what Dingbo introduce to you about the correct maintenance and operation of diesel generator accessories. If you have any questions welcome visit our website or send email to us [email protected], we will very happy to serve you.

Share

Contact Us

  • Add.: No. 10 Kechuang Road, High tech Zone, Nanning, Guangxi, China
  • Tel.: +86 771 5805 269
  • Fax: +86 771 5805 259
  • Cellphone: +86 134 8102 4441
                    +86 138 7819 8542
  • E-mail: [email protected]
Follow Us

Copyright © Guangxi Dingbo Generator Set Manufacturing Co., Ltd. All Rights Reserved | Sitemap

Update cookies preferences

generator set:

Emergency vs Standby Generator: What’s The Difference? Commercial Generators Trailer Mounted Water Pumps for Sale
Contact Us