Home Products News Contact Us
Home > News > Can Diesel Generator Set Fuel and Engine Oil Be Mixed?

Can Diesel Generator Set Fuel and Engine Oil Be Mixed?

Aug. 04, 2023

The fuel and engine oil of a diesel generator set have completely different functions. They cannot be mixed. Once the fuel and engine oil are mixed, it means that there is a problem with the sealing of the diesel generator set. This situation occurs from time to time in use. The power generation equipment will give you an answer to the treatment method of the diesel generator set after the fuel and the engine oil are mixed.


 500kw 625kva Perkins Diesel Generator Set


1. The pump membrane of the oil transfer pump is rotten or degummed, so that the diesel oil flows into the oil pan and mixes with the engine oil. Remove the oil transfer pump, and add corresponding pressure to the oil inlet and outlet pipes on the oil pump test bench. If no diesel leakage is found, the oil transfer pump is intact.


2. The opening pressure of the fuel injector is low, and the atomization is not good, so that the diesel fuel flows into the oil pan along the cylinder wall to mix with the engine oil. Remove the fuel injector and test it on the high-pressure fuel pump test bench. If the opening pressure of the fuel injector meets the requirements and the atomization is good, the fuel injector is intact. Otherwise, it must be repaired or replaced.


3. The front end of the fuel injection pump is leaking, that is, the front end of the fuel injection pump is ineffective. Remove the inspection hole cover of the gear chamber cover. If a large amount of diesel is sprayed from behind the drive gear of the fuel injection pump, it can be concluded that the diesel is leaking into the fuel from the fuel injection pump. The bottom shell is mixed with engine oil.


Dismantling the fuel injection pump of the diesel generator set and testing on the high-pressure fuel pump test bench; many fuel injection pump front gear shaft journals are deformed, a large amount of diesel leaks, and the oil seal seat has the traces (indentation marks) when the gear is removed by the special tool. ) The oil seal seat and the oil seal are deformed, causing diesel oil leakage. Finally, replace the fuel injection pump, and the failure can be dealt with.


As a professional diesel generator manufacturer, we always insist on using first-class talents to build a first-class enterprise, create first-class products, create first-class services, and strive to build a first-class domestic enterprise. If you would like to get more information welcome to contact us via [email protected].

Share

Contact Us

  • Add.: No. 10 Kechuang Road, High tech Zone, Nanning, Guangxi, China
  • Tel.: +86 771 5805 269
  • Fax: +86 771 5805 259
  • Cellphone: +86 134 8102 4441
                    +86 138 7819 8542
  • E-mail: [email protected]
Follow Us

Copyright © Guangxi Dingbo Generator Set Manufacturing Co., Ltd. All Rights Reserved | Sitemap

Update cookies preferences

generator set:

Emergency vs Standby Generator: What’s The Difference? Commercial Generators Trailer Mounted Water Pumps for Sale
Contact Us