Home Products News Contact Us
Home > News > A 8kW Silent Diesel Genset and A 200kW Generator Set Were Exported to Algeria

A 8kW Silent Diesel Genset and A 200kW Generator Set Were Exported to Algeria

Sep. 03, 2024

In December, 2023, Dingbo Power produced a 8kW silent diesel generator and a 200kW diesel genset for a client from Algeria. After being factory tested and certified, the generator sets were delivered to the client successfully. Thanks for the client’s support.


Information about 200kW diesel generator set


Manufacturer: Guangxi Dingbo Generator Set Manufacturing Co.,Ltd.

Genset model: DB-200GF

Type: open type

Prime/standby power: 200kw/220kw

Rated voltage: 400/230V

Rated Current: 360A

Speed/frequency: 1500rpm/50Hz

Power factor: 0.8lag

Phase & Wire: 3 Phase 4 Wire

Diesel engine: Cummins 6LTAA8.9-G2

Alternator: Leroy Somer TAL-A46-D

Controller: SmartGen HGM6120


This diesel generator set is powered by a Cummins 6LTAA8.9-G2 engine and coupled with a  Leroy Somer TAL-A46-D alternator and a SmartGen HGM6120 controller. It is equipped with a 400A Schneider circuit breaker and a 400A 4P ABB vertical ATS. The genset can provide strong and reliable power with relatively low fuel consumption, low noise and low vibration. It can fit a wide range of industrial and commercial applications, such as construction projects, data centers, healthcare facilities and so on.


A 8kW Silent Diesel Genset and A 200kW Generator Set Were Exported to Algeria


Cummins 6LTAA8.9-G2 Specifications


Engine Model: 6LTAA8.9G2

Engine Manufacturer: DONGFENG CUMMINS ENGINE Co., Ltd.

Cylinder quantity: 6

Air intake way: Air-air after-cooled, turbo-charged

Bore x Stroke (mm x mm):114×135

Displacement: 8.9L

Compression Ratio: 16.5:1

Prime power / Speed (KW/RPM) 220/1500

Standby power/ Speed (KW/RPM) 240/1500

Coolant capacity-engine only: 11.1L


Leroy Somer TAL-A46-D Specifications


Alternator model: TAL-A46-D

Alternator manufacturer: Leroy Somer

Excitation system: SHUNT AREP/PMG

Rated speed/frequency: 1500 rpm/50Hz

Rated voltage: 400/230V

Continuous/Standby Ratings: 250 KVA/275kVA

Number of phase: 3

Power factor: 0.8

Voltage regulation: ±1%

Insulation grade: H

Protection grade: IP23


Understand the importance of regular generator maintenance


After buying a new diesel generator set, you need to follow the manufacturer’s instructions and recommendations to operate the genset. The generator set should be maintained regularly to ensure they will work smoothly and efficiently when needed. Routine generator maintenance minimizes the risk for accidents, damage, and more costly repairs down the line. It can prevent costly downtime or damage due to malfunction.


Generally, most manufacturers recommend that generators be serviced at least once a year or after every 100-200 hours of operation. Maintenance operations should be performed more frequently if your generators operate in environments subject to temperature extremes and/or dusty conditions.


Some tips to maintain your diesel generator set:


It is a good idea to establish and adhere to a schedule of maintenance and service based on your diesel generator's usage. You can conduct daily, weekly, monthly, and yearly inspections to make sure your generator set is in good condition and can work efficiently in an emergency situation.


Routine inspections are a key part of generator maintenance. When the generator is running, you need to pay attention to any mechanical problems that could create unsafe or hazardous conditions. Check the exhaust system, fuel system, DC electrical system and engine completely. Look for concerns like corrosion, loose connections or leaks. Check if there is any odd noises in the generator set. Monitor fluid levels, oil pressure and coolant temperatures frequently. If any problem is discovered, fix it timely to prevent major problems in the future.


Over time, your diesel generator filters can become clogged, fuel injectors can become dirty, and batteries can become weak. Thus, you need to regularly change the quick-wear parts, such as oil filters, air filters, fuel filters to ensure optimal performance of the generator set. It’s also necessary to check and adjust valve clearance, ignition timing and other parameters. Battery failure can cause the generator set not starting problem. Check the battery terminals for any signs of corrosion and clean them regularly.


A well maintained diesel generator can provide you reliable power during critical situations. If you are unsure about the generator maintenance or looking for a new diesel generator, get in touch with Dingbo Power today!


Share

Contact Us

  • Add.: No. 10 Kechuang Road, High tech Zone, Nanning, Guangxi, China
  • Tel.: +86 771 5805 269
  • Fax: +86 771 5805 259
  • Cellphone: +86 134 8102 4441
                    +86 138 7819 8542
  • E-mail: [email protected]
Follow Us

Copyright © Guangxi Dingbo Generator Set Manufacturing Co., Ltd. All Rights Reserved | Sitemap

Update cookies preferences

generator set:

Emergency vs Standby Generator: What’s The Difference? Commercial Generators Trailer Mounted Water Pumps for Sale
Contact Us