Home Products News Contact Us
Home > News > A 40kW Cummins Silent Diesel Generator Set Was Exported to Armenia

A 40kW Cummins Silent Diesel Generator Set Was Exported to Armenia

Apr. 18, 2025

In August 2024, a valued client from Armenia placed an order for a 40kW diesel generator set with Dingbo Power. The ordered generator set is designed to meet the client’s specific requirements, being powered by a Cummins diesel engine and coupled with a Shanghai Stamford alternator and a SmartGen controller. The unit ensures optimal efficiency for both primary and backup applications.


Main technical data of 40kW diesel generator set


Manufacturer: Guangxi Dingbo Generator Set Manufacturing Co.,Ltd.

Genset model: DB-40GF

Type: Silent type

Prime Power: 40KW/50KVA

Standby power: 44KW/55KVA

Rated voltage: 400/230V

Rated Current: 72A

Speed/frequency: 1500rpm/50Hz

Power factor: 0.8lag

Phase & Wire:3 Phase 4 Wire

Diesel engine: Cummins 4BTA3.9-G2

Alternator: Shanghai Stamford GR225D

Controller: SmartGen 6110N-4G-G

Base bottom fuel tank: 8 hours operation

Noise level: 75dBA at 7 meters


A 40kW Cummins Silent Diesel Generator Set Was Exported to Armenia


Diesel engine


Manufacturer:Dongfeng Cummins Engine Co.,Ltd
Engine model4BTA3.9-G2
Prime power:50KW
Standby power:55KW
Frequency/Speed:50Hz/1500RPM
Cylinders no. & Type:4 cylinders, In line, 4 stroke, diesel engine, water-cooled with radiator with fan
Aspiration:Water Aftercooled
Displacement:3.9L
Compression ratio17.3:1
GovernorElectronic speed control
Bore x Stroke(mm):102x 120mm
Start mode:Electric start
Starter motor:24V DC, negative ground
Fuel injectionDirect injection
Coolant capacity(Engine Only)8.3L
Cooling wayWater-cooled
Maximum Oil Temperature121℃
Minimum Required Lube System Capacity - Sump plus Filters10.9L
Thermostat (Modulating) Range82~95℃
Fuel consumption at standby power100%: 16.5L/h
Fuel consumption at Prime power100%: 14.9L/h 75%: 11.4L/h50%: 8.1L/h25%: 4.8L/h


Alternator


ManufacturerShanghai Stamford Power Equipment Co.,Ltd
Alternator modelGR225D
Prime power40KW
Wire connecting methodY type, 3 phase 4 wire
Power Factor:0.8lag
Efficiency:92.8%
Regulator:AVR
Rotor:Single/double bearing
Exciter type:Brushless Self-Excited
Recovery time(Tr)1s
Waveform : TIF<50
Waveform : THF<2%
Winding Pitch2/3
Voltage regulation:± 1.0 %
Protection:IP23
Insulation classH
Temperature rise grade:H


Controller


Manufacturer: SmartGen

Model: 6110N-4G-G

Port: RS485, CANBUS

Communication protocol: MODBUS


This automatic controller, integrating digital, intelligent and network techniques, is used for automatic control and monitoring system of genset. It can carry out functions of automatic start/stop, data measurement, alarm protection and three remote (remote control, remote measure and remote communication). Users can monitor the genset and inquire the genset running status, the event log, as well as configure the parameters via cloud server by phone APP (ISO or Android) and computer terminal equipment.


Alarm & shutdown items are included:

Low Coolant Level

High coolant temperature

Low oil pressure

Low output frequency

High output frequency

Low output voltage

High output voltage

Low Fuel Level

Emergency stop


Crafted as a silent-type unit, the 40kW generator set incorporates a 2mm thick galvanized steel enclosure to minimize operational noise, achieving an impressive noise level of 75dB(A) at 7 meters. This design ensures compliance with stringent environmental standards while enabling installation in noise-sensitive areas. Additional safety and convenience features include a Suyang 125A circuit breaker for enhanced electrical protection and an integrated 8-hour base fuel tank with a fuel level sensor for real-time monitoring.


As a professional manufacturer of diesel generator sets in China since 2006, Dingbo Power specializes in designing, producing, and servicing diesel power generators ranging from 20kW to 3000kW. Our product portfolio includes silent, trailer-mounted, containerized, and open-type units, all backed by global certifications and 24/7 technical support.


For inquiries, contact [email protected].


Share

Contact Us

  • Add.: No. 10 Kechuang Road, High tech Zone, Nanning, Guangxi, China
  • Tel.: +86 771 5805 269
  • Fax: +86 771 5805 259
  • Cellphone: +86 134 8102 4441
                    +86 138 7819 8542
  • E-mail: [email protected]
Follow Us

Copyright © Guangxi Dingbo Generator Set Manufacturing Co., Ltd. All Rights Reserved | Sitemap

Update cookies preferences

generator set:

Emergency vs Standby Generator: What’s The Difference? Commercial Generators Trailer Mounted Water Pumps for Sale
Contact Us