Home Products News Contact Us
Home > News

Starlight Cummins Diesel Generators Used in Real Estate

Jan. 07, 2020

In December, Starlight company and Liujiang Huateng Real Estate Development Co., Ltd., a subsidiary of Hejing Taifu Group, successfully signed a 600KW and a 640KW Cummins diesel generator sets. These two units are used as emergency standby power for the first and second phase of the Yunxi Four Seasons Garden.


This is the second cooperation between our company and Hejing Taifu Group. Prior to this, our company has signed two sets of 520KW and 640KW Cummins diesel generators used in different projects of the Real Estate.


In this project cooperation, in addition to the supply of the diesel generator sets, Starlight is also responsible for the installation and supporting environmental protection inspection and acceptance of the project, including: installation of diesel generating set and supporting environmental protection installation project, completion of equipment design and environmental design, manufacturing, testing, transportation, installation and commissioning, operation, acceptance and cooperation for environmental protection completion acceptance and other related services.


Cummins diesel generator set


600KW & 640KW 50Hz 1500rpm 400V Cummins Diesel Generator Set Standard Features:

1. Radiator 50°C max

2. Fans are driven by belt, with safety guard

3. 24V charger alternator

4. 24V starter motor

5. Dry type air filter, fuel filter, oil filter

6. Shock pad

7. Muffler

8. Main circuit breaker, ATS is optional

9. IP23, Class H, 3 phase 4 wire

10. 24V free-maintenance battery, a set of maintenance tool, etc.

Reference Standards:

BS-5514 and DIN-6271 standards are based on ISO-3046.

Operation At Elevated Temperature And Altitude:

The engine speed is 1500r / min, the altitude is lower than 15000m (5000ft), and the ambient temperature is lower than 40°C (104°F).

The engine runs above the above conditions. When the altitude is higher than 1500m (5000ft), the power is reduced by 4% for every 300m (1000ft) increase; when the ambient temperature is higher than 40°C (104°F), the power is reduced by 2% for every 11°C increase (10°F increase, 1% decrease).


600KW Cummins Generator Basic Configuration:

Engine: Cummins / KTA38-GA

Prime power: 647 KW

Standby power: 711 KW

Type: 4 cycle, V type, 12 cylinder

Aspiration: Turbocharged

Bore and stroke: 159 x 159 mm

Displacement: 38 L

Compression ratio: 14.5:1

Fuel system: Cummins PT

Alternator: Stamford / LVI634B1

Controller: Deep Sea / 7320 MKII


640KW Cummins Generator Basic Configuration:

Engine: Cummins / KTA38-G2

Prime power: 664 KW

Standby power: 731 KW

Type:  4 cycle, V type, 12 cylinder

Aspiration: Turbocharged

Bore and stroke: 159 x 159 mm

Displacement: 38 L

Compression ratio: 14.5:1

Fuel system: Cummins PT

Alternator: Stamford / LVI634C1

Controller: Deep Sea / 7320 MKII


The two diesel generator sets use the Sino-US joint venture Cummins engine. It has the characteristics of small size, light weight, low fuel consumption, low noise, high output power, convenient supply and maintenance of parts, and its reliable stability, economy, and power performance, durability and environmental safety are welcomed by users at home and abroad.


Starlight is one of leading manufacturers of diesel generator sets in China. With strong research and development strength, modern production technology, professional manufacturing technology, advanced testing equipment, perfect quality management system, we can provide various types of automatic diesel generator sets for customers to choose, but also to meet users’ demand of different voltage and frequency.


As the largest Cummins diesel genset OEM cooperative manufacturer in China, we can provide 20 KW to 2400 KW new diesel generators powered by Cummins engine. If you have a plan to purchase Cummins generator, please send an inquiry to sales@dieselgeneratortech.com.

Share
Contact Us
  • Adds: No.2 Xingguang Road, Guxi Industrial Park, Taixing, Jiangsu, China.
  • Tel: +86 771 5805 269
  • FAX: +86 771 5805 259
  • Cellphone: +86 134 8102 4441
                    +86 138 7819 8542
  • E-mail: sales@dieselgeneratortech.com
Follow Us

Copyright © Jiangsu Starlight Electricity Equipments Co., Ltd.All Rights Reserved | Sitemap

Contact Us