Sep. 02, 2025

After the acceptance of diesel generator sets, Dingbo Power, the diesel generator manufacturer, arranges operational training for users. Today’s training topic is "When to Use the Emergency Stop Button". There is an emergency stop button on the control panel of diesel generator sets. As the name suggests, it is used to trigger protective measures by pressing it quickly in case of emergencies. It should only be pressed when the unit suddenly malfunctions or the electrical load encounters an unexpected situation that prevents normal shutdown procedures.


power generation


In the event of a sudden failure of the generator set or other emergencies, the emergency stop button must be pressed. Notably, after the machine shuts down, the emergency stop button should be reset. Pressing the button directly downward immediately halts the entire equipment. To restart, the button must be released: rotate it clockwise by approximately 45°, then release, and the pressed part will pop up, indicating "release". Failure to reset the button will prevent the diesel generator set from restarting.

 

Dingbo Power reminds users: If operators detect severe unit failures or power distribution faults, they may press the emergency stop button on the control panel to shut down the unit immediately. Under normal circumstances, users are not advised to shut down the unit using the emergency stop button arbitrarily.

 

Normal Shutdown Procedure for Diesel Generators: Before normal shutdown, first disconnect the load, then let the unit run at no load for a certain period to allow sufficient cooling. For units equipped with a shutdown valve, turning off the control panel key switch to stop the unit is ineffective. The correct shutdown operation requires pressing the stop button on the control panel while it is powered on.

 

Since 1982, Dingbo Generator has been a generator set manufacturer qualified by the "National Internal Combustion Engine Quality Supervision and Inspection Center". The product quality has passed the IS09001 quality system standard certification. And obtained the qualification certificate for self-operated import and export. Over the years, Dingbo units have been widely used in all walks of life, and have won the network access qualification of the Ministry of Information Industry, the network access qualification of the Ministry of Radio and Television, the network access qualification of CNPC, the network access qualification of China Mobile, and the manufacturing qualification of marine units. In 2016, Dingbo was awarded the Certificate of Qualified Supplier of China Nuclear Power Group. Dingbo Generator has been cooperating with Shangchai Power for many years. In 2009, it became the OEM partner of Shangchai Power in China. Dingbo generator VOLVO unit ranks the top three in the Asia-Pacific sales volume, and is the core OEM partner of Sweden Volvo in the Asia-Pacific region. If any question please feel free to visit our website https://www.dieselgeneratortech.com/ or send email to [email protected].

Contact Us

  • Add.: No. 10 Kechuang Road, High tech Zone, Nanning, Guangxi, China
  • Tel.: +86 771 5805 269
  • Fax: +86 771 5805 259
  • Cellphone: +86 134 8102 4441
                    +86 138 7819 8542
  • E-mail: [email protected]
Follow Us

Copyright © Guangxi Dingbo Generator Set Manufacturing Co., Ltd. All Rights Reserved | Sitemap

Update cookies preferences

generator set:

Emergency vs Standby Generator: What’s The Difference? Commercial Generators Trailer Mounted Water Pumps for Sale
Contact Us