Cummins generator sets have undergone significant performance upgrades. The details are summarized as follows:

1. Application Scope of Cummins Automatic Generator Sets

Automatic diesel generators are widely used in factories, banks, post and telecommunications, hospitals, high-rise buildings, commercial buildings, industrial and mining enterprises, oil fields, highways, ports and stadiums as general or emergency power sources for communications, power and lighting.


Dongfeng Cummins generator


2. Unit Design in Structure and Application

The diesel generator has an advanced control system in its structural and application design, using a dedicated program controller. When the mains power is lost, phase-deficient, or under-voltage, it can automatically start the unit and put it into operation for power supply; when a fault occurs, the sound alarm device will automatically alarm, can memorize the fault point, and at the same time can automatically unload and stop to ensure the safety of the unit. The control panel adopts a full Chinese light display screen and soft touch switches, with clear display and reliable operation. At the same time, control panels for more than two units can be designed, making the adjustment process very fast, accurate, stable and reliable.

 

3. Performance Introduction of Cummins Automatic Generator

A. Automatic Start and Input Function

When the power supply stops or the power supply voltage is lower than 80% of the rated value, the unit will start automatically. After successful start-up, it will supply power to the load. The entire process of a successful start-up is controlled within 15 seconds. It has a remote interface, can set the start delay, and realize the automatic start and stop of the generator set.

B. Automatic Exit Function

During the self-generated power output of the generator set in the automatic state, if the mains power is restored and confirmed after 30 seconds, the unit starts to execute the automatic exit procedure. The unit will first cut off the load, restore the mains power supply, and then automatically stop after 2 minutes of cold running. If the power supply is stopped during the operation of the chiller, the unit automatically adjusts to high speed and restores power supply to the load.

C. Pre-alarm/Fault Protection Function

Low battery voltage, charging failure, overcurrent, low oil pressure, high water temperature, etc. have alarm functions, that is, the value in the alarm does not stop, and the alarm light flashes at this time; when the value exceeds the stop value, the engine stops due to fault, low speed, overspeed, frequency overrun, voltage overrun, start fault protection function. If an analog input value is greater than the upper limit or less than the lower limit, the corresponding high/low delay is started. After the delay ends, if the value does not return to normal, the oil engine stops immediately and the alarm light is on for a long time.

D. Automatic Charging Function

During the power-on or self-generating period of the unit, it can automatically charge the starting control battery. The charging system adopts a switching power supply, which can charge the battery in two stages.

 

As a professional diesel generator manufacturer, we always insist on using first-class talents to build a first-class enterprise, create first-class products, create first-class services, and strive to build a first-class domestic enterprise. If you would like to get more information welcome to contact us via [email protected].

Contact Us

  • Add.: No. 10 Kechuang Road, High tech Zone, Nanning, Guangxi, China
  • Tel.: +86 771 5805 269
  • Fax: +86 771 5805 259
  • Cellphone: +86 134 8102 4441
                    +86 138 7819 8542
  • E-mail: [email protected]
Follow Us

Copyright © Guangxi Dingbo Generator Set Manufacturing Co., Ltd. All Rights Reserved | Sitemap

Update cookies preferences
Contact Us