Starlight Power is a diesel generator manufacturer, as well as the OEM supporting office center of Volvo generator. Volvo is a industrial enterprise in Sweden, the quality of its diesel generator is very high, Volvo company has 120 years history, one of the world's oldest engine manufacturers. So far, its diesel engine quantity has over one million sets, and widely used for car, engineering plant, steamer etc. It is also the ideal power for diesel generator set.
Starlight Volvo diesel generator set has fast and reliable cold start performance, optimum design shock absorber, low running cost of continuous load and low speed cooling fan. It adopts advanced technology to optimize combustion process, accurately matched turbocharger, also can reduces running noise. And the emission reaches the German TALUFT standard. The emission of EFI machine is better than that of German TALUFT standard.
Here is some advantages of Volvo diesel generator set:
1.Power range: 75kw-616kw;
2.Powerful load bearing capacity;
3.Engine running smoothly and low noise;
4.Reliable cold start performance;
5.Exquisite and compact appearance design;
6.Low fuel consumption and operation cost. Small exhaust gas emission, economy and environmental protection;
7.There are service centers and spare parts suppliers all over the world.
Specifications of Starlight 300kw Volvo diesel generator set
Starlight Volvo diesel generator model | XG-300GF | ||
Genset power | Prime | Standby | |
300kw | 330kw | ||
Diesel engine model | TAD1343GE | ||
Diesel engine power | 323kw | 355kw | |
Diesel engine manufacturer | Sweden Volvo Penta | ||
Engine structure | 6 in line, 4 stroke, Turbocharged & Intercooled, EFI fuel system | ||
Engine cooling way | Water cooling, Belt driven cooling fan, safety cover with fan | ||
Speed regulating system | Electronic monitoring and management system | ||
Start mode | 24V DC | ||
Engine filter system | Dry air filter, oil-water separator, fuel filter, oil filter, oil filter, oil filter through the filter, cooling filter | ||
Fuel system | Full electronic fuel injection system | ||
Total engine displacement | 12.13L | ||
Compression ratio | 17.5:1 | ||
Bore x stroke | 131 x 150mm | ||
100% load fuel consumption | 86.0 L/h | 95.7L/h | |
Exhaust air volume | 510㎡/min | ||
Gas capacity | 24.0 ㎡/min | 26.0㎡/min | |
Smoke exhaust capacity | 64.0㎡/min | 69.0㎡/min | |
Smoke temperature | 505℃ | 525℃ | |
Engine Oil capacity | 35L | ||
Coolant capacity | 44L | ||
Short circuit protection | MCC air switch | ||
Rated voltage/frequency/ Power factor | 230/400V, 50Hz, 1500rpm, 0.8lag | ||
Steady frequency adjustment rate | 0~5% | ||
No-load voltage adjustment range | ≧95%~105% | ||
Steady voltage adjustment rate | >±1% | ||
Protection level | H/IP23 |
The engine TAD1343GE for Starlight Volvo 300kw diesel generator is designed for efficient power generation and maximum uptime. The robust design makes the engine highly reliable. Its rigid, in line cylinder block with durable crankshaft bearings, aircooled exhaust manifold, and electronically controlled, wastegate turbo provide a very powerful engine. The smooth operation of this both robust and well balanced diesel engine results in minimal levels of vibrations and noise, as well as controlled emission levels. So that make Volvo generator is with good performance.
Even if Volvo diesel generator is very reliable and high quality, if you have Volvo diesel generator, during use, you should also pay attentions to something:
Avoid prolonged idle and low load operation, this operation will result in problems as follows:
1.Increased lubricant consumption;
2.Leakage of fuel or lubricant in exhaust manifold;
3.Leakage of oil from turbine shaft seal of turbocharger;
4.Serious carbon deposit on piston, piston ring groove, valve and supercharger;
5.Low combustion temperature will cause incomplete combustion of fuel, resulting in dilution of lubricant.
Why use certified Volvo diesel engine air filter?
1.Bad air filtration will lead to worsening engine wear. For a continuous working engine, it may take only a few hours to damage the cylinder liner and cylinder;
2.This unnecessary wear greatly shortens the time from the engine to the next overhaul and can damage the engine under extreme conditions;
3. Other effects, for example poor filtration or filter blockage are increased fuel and lubrication consumption and reduced engine performance.
Starlight Power manufacturer always provides high quality and certified diesel generator set to every customer, at the same, also provides professional after-sale service. Contact us to get the best product and service.
Copyright © Guangxi Dingbo Power Equipment Manufacturing Co., Ltd. All Rights Reserved | Sitemap