Diesel generator manufacturer Dingbo Power has always been dedicated to the production of diesel generator sets. Service is the second most powerful weapon of our company. For an enterprise to develop, it depends on quality and service. In the process of our service over the years, we've found that many customers think the higher the oil level in the oil pan of a diesel generator, the better. However, everything should be viewed from two sides.


150kva generator price


The oil level in the oil pan of a diesel engine should not be too low. If the oil level is too low, it will result in poor lubrication and an excessively high oil temperature, leading to early wear of mating parts. Especially when going downhill, passing over bumps, or making an emergency stop, the oil strainer may be exposed above the oil level, sucking air into the oil pump and causing a failure to supply oil, resulting in serious accidents such as "shaft seizure" and "bearing burnout".

 

On the other hand, the oil level in the oil pan is not the higher the better either. When the oil level is too high, the oil can easily enter the combustion chamber, causing the exhaust pipe to emit oil and blue smoke. This not only wastes oil and increases consumption but also generates a large amount of carbon deposits due to incomplete combustion of the oil, aggravating the wear between the piston and the cylinder liner, and between the valve and the valve seat. It may even cause the piston ring to seize, seriously affecting the normal operation of the diesel engine.

 

Generally, there is a dipstick inserted into the oil pan of a diesel engine to measure the oil level, simply called the oil dipstick. There are two points or two lines on it (i.e., points or lines A - B). The oil level in the oil pan of a diesel engine must be between points (lines) A and B of the oil dipstick.

 

Steps to check the oil level:

1.Pull out the oil dipstick.

2.Wipe the oil dipstick clean with a clean, lint - free cloth.

3.Insert the oil dipstick as deeply as possible until it can't be inserted any further.

4.Pull out the oil dipstick again.

5.Check the oil level. The oil level should not be lower than the minimum oil level A or higher than the maximum oil level B. Otherwise, you need to drain or add oil.

 

Guangxi Dingbo Power Equipment Manufacturing Co.,Ltd was founded in 1974 and is one of the earliest manufacturers of generators and diesel generator sets in China. The company has a registered capital of 218.88 million yuan. The company covers an area of 86,000 square meters and a building area of 55,000 square meters. There are more than 660 employees, including 456 professional technicians and 106 senior technicians. It has 46 sales and service outlets nationwide. The main products are diesel engines, generator sets, and diesel generators, providing users with a one-stop service of design, supply, debugging and maintenance at any time. Dingbo has always insisted on using first-class talents, building first-class enterprises, manufacturing first-class products, creating first-class services, and making every effort to build a first-class domestic enterprise. If any question please feel free to visit our website https://www.dieselgeneratortech.com/ or send email to [email protected].

Contact Us

  • Add.: No. 10 Kechuang Road, High tech Zone, Nanning, Guangxi, China
  • Tel.: +86 771 5805 269
  • Fax: +86 771 5805 259
  • Cellphone: +86 134 8102 4441
                    +86 138 7819 8542
  • E-mail: [email protected]
Follow Us

Copyright © Guangxi Dingbo Generator Set Manufacturing Co., Ltd. All Rights Reserved | Sitemap

Update cookies preferences

generator set:

Emergency vs Standby Generator: What’s The Difference? Commercial Generators Trailer Mounted Water Pumps for Sale
Contact Us