The mobile trailer generator set, also known as a mobile power station, is characterized by its mobility. It is highly needed in fields such as field engineering construction, emergency rescue, disaster relief, mining, military, and communication to improve the convenience of people's work in these areas. What issues should be noted when using a mobile trailer generator set? Diesel generator manufacturer Guangxi Dingbo Electric summarizes the following points, hoping to be helpful to users of mobile trailer generator sets.


generator trailer manufacturers


After the mobile trailer generator set (mobile power station) is put into normal use, its operating status should be closely monitored. The indication values of all instruments should be frequently monitored and the overall operating status of the machine should be observed. The cooling system and some lubricating oil levels should be checked regularly. If any non-compliance or leakage is found, the cause should be immediately supplemented or checked to eliminate the fault of the mobile trailer generator set.

 

1. The working temperature of the mobile trailer generator set cannot be too low. When it is too low, the wear rate of the parts will accelerate, and the cylinder liner is also prone to cavitation. In addition, at low temperatures, lubricating oil has high viscosity and poor fluidity, which makes it difficult to enter the lubricating surface in a timely manner, and the fit between the piston and the cylinder is poor, making it easy to burn the engine oil. Therefore, it is generally stipulated that after the diesel generator set is started, the vehicle must be warmed up at a medium speed. The vehicle can only start driving when the water temperature reaches 40 ℃ or above, and can only operate with load after the water temperature reaches 60 ℃.

 

2. When using in winter, attention should be paid to antifreeze. After using the mobile trailer generator set, the cooling water should be drained to avoid freezing and damaging the body. Antifreeze can also be added to the cooling system to prevent the cooling water from freezing. If the temperature of the cooling water is too high before draining, the mobile trailer diesel generator set should be operated at low speed for a period of time, and the water should be drained after the temperature drops to avoid deformation or cracking of the cylinder head and cylinder block due to rapid temperature changes.

 

3. Pay attention to checking the tension of the fan belt. For diesel generator sets with natural convection cooling system, it is necessary to regularly check the tension of the fan belt during use. If the belt is too tight, it will accelerate the wear of the components and belt; The belt is too loose and the fan speed is not enough, which affects the cooling effect.

 

During the operation of the mobile trailer generator set, especially when the load is suddenly reduced, attention should be paid to preventing the diesel engine speed from suddenly increasing beyond the specified value due to the failure of the governor. Guangxi Dingbo Electric Power recommends that once such a situation occurs, emergency parking measures should be taken quickly, and then the cause should be identified and repaired.

 

Dingbo Power was founded in 1974 and is one of the earliest manufacturers of generators and diesel generator sets in China. If you want get more information, please feel free to send email to [email protected] we will pay highly attention on your question.

Contact Us

  • Add.: No. 10 Kechuang Road, High tech Zone, Nanning, Guangxi, China
  • Tel.: +86 771 5805 269
  • Fax: +86 771 5805 259
  • Cellphone: +86 134 8102 4441
                    +86 138 7819 8542
  • E-mail: [email protected]
Follow Us

Copyright © Guangxi Dingbo Generator Set Manufacturing Co., Ltd. All Rights Reserved | Sitemap

Update cookies preferences

generator set:

Emergency vs Standby Generator: What’s The Difference? Commercial Generators Trailer Mounted Water Pumps for Sale
Contact Us