For many new users who purchase diesel generator sets, they may encounter this problem. When you receive and open the diesel generator set, you will find that the picture shows the voltage as 430V and the frequency as 52.5HZ. The frequency is higher than 50HZ? And the voltage is also higher than 400V? In fact, this is a normal fluctuation range. Because the unit has no load, the frequency and voltage will increase somewhat. After being loaded, it will decrease. Therefore, this voltage frequency is within the normal range and there is no need to worry.


1000kw diesel generator


In view of this phenomenon, the diesel generator manufacturer Dingbo Power hereby summarizes and shares with customers some allowable variation ranges of the unit for reference:

 

1.The diesel generator set can run continuously at full load for 12 hours, and its overload capacity for 1 hour is 110%. The generator has an over - current capacity of 1.5 times for 15 seconds, and it is allowed to repeat this operation mode after a period of time;

 

2.Under any steady - state load condition, maintain the voltage within ±1% and the frequency within ±0.5% of the rated value deviation;

 

3.In the transient state of sudden start - up with load, the voltage is not less than 90%, the frequency is not less than 95%, and the recovery time is within 7 seconds. The transient process is due to the unit carrying loads in batches from no - load;

 

4.If the motor starts directly, the current is considered to be 6.5 times. It can start automatically within 7 - 10S after the power is cut off, and establish the voltage frequency to reach the rated value. The diesel generator can carry 50% of the starting load of the rated capacity, of which the maximum starting load is allowed to supplement 20% of the rated capacity of the generator. Full load can be carried after 5S;

 

5.The voltage regulation range is ±5%, and the frequency regulation range is ±2.5%;

 

6.The diesel generator set can reach the rated speed and rated voltage within 15S after receiving the starting signal, and has the full - load condition.

 

Guangxi Dingbo Power Equipment Manufacturing Co.,Ltd was founded in 1974 and is one of the earliest manufacturers of generators and diesel generator sets in China. The company has a registered capital of 218.88 million yuan. The company covers an area of 86,000 square meters and a building area of 55,000 square meters. There are more than 660 employees, including 456 professional technicians and 106 senior technicians. It has 46 sales and service outlets nationwide. The main products are diesel engines, generator sets, and diesel generators, providing users with a one-stop service of design, supply, debugging and maintenance at any time. Dingbo has always insisted on using first-class talents, building first-class enterprises, manufacturing first-class products, creating first-class services, and making every effort to build a first-class domestic enterprise. If any question please feel free to visit our website https://www.dieselgeneratortech.com/ or send email to [email protected].

Contact Us

  • Add.: No. 10 Kechuang Road, High tech Zone, Nanning, Guangxi, China
  • Tel.: +86 771 5805 269
  • Fax: +86 771 5805 259
  • Cellphone: +86 134 8102 4441
                    +86 138 7819 8542
  • E-mail: [email protected]
Follow Us

Copyright © Guangxi Dingbo Generator Set Manufacturing Co., Ltd. All Rights Reserved | Sitemap

Update cookies preferences

generator set:

Emergency vs Standby Generator: What’s The Difference? Commercial Generators Trailer Mounted Water Pumps for Sale
Contact Us