Cummins 250 kw diesel generator


After the disassembly of the Cummins diesel generator oil delivery pump, check the wear of the inlet and outlet valves and valve seats: if there are cracks or severe wear, they should be replaced; If there is slight wear, it can be ground and repaired; If the piston and housing of the oil delivery pump are loose or move unevenly due to wear, the pump should be replaced with a new one.


If there are signs of wear, dents, pits, etc. on the plane of the one-way valve, grinding paste should be used to grind it on the flat plate. In severe cases, a new one should be replaced. The surface of the one-way valve seat on the housing is severely worn or uneven, which should be replaced. If the top rod and top rod sleeve are severely worn, resulting in large gaps, poor sealing, and severe diesel leakage, they must be replaced together with the casing, or an oversized top rod must be selected, but mutual research is required.


The coarse filter core inside the oil inlet pipe joint is easily blocked by cotton like debris, which can affect fuel supply. Therefore, it is necessary to regularly pay attention to fuel cleaning and remove dirt from the filter core. When the rubber ring of the hand pump piston is damaged, it should be replaced in a timely manner. The oil leakage at the piston of the hand pump used in the 12 cylinder V-type diesel engine indicates wear on the mating surface and a large gap, which requires re selection.


After the reassembly of the Cummins diesel generator oil pump, it is required that the piston and top rod of the oil pump and other moving parts should move well throughout the entire stroke without any obstruction or jamming. The pressure pump should be lightweight and flexible, and attention should be paid to the installation of the one-way valve spring. The one-way valve spring must be accurately embedded in the spring groove.


Guangxi Dingbo Generator Set Manufacturing Co.,Ltd was founded in 1974 and is one of the earliest manufacturers of generators and diesel generator sets in China. The company has a registered capital of 218.88 million yuan. The company covers an area of 86,000 square meters and a building area of 55,000 square meters. There are more than 660 employees, including 456 professional technicians and 106 senior technicians. It has 46 sales and service outlets nationwide. The main products are diesel engines, generator sets, and diesel generators, providing users with a one-stop service of design, supply, debugging and maintenance at any time. Dingbo has always insisted on using first-class talents, building first-class enterprises, manufacturing first-class products, creating first-class services, and making every effort to build a first-class domestic enterprise. If any question please feel free to visit our website https://www.dieselgeneratortech.com/ or send email to [email protected].

Contact Us

  • Add.: No. 10 Kechuang Road, High tech Zone, Nanning, Guangxi, China
  • Tel.: +86 771 5805 269
  • Fax: +86 771 5805 259
  • Cellphone: +86 134 8102 4441
                    +86 138 7819 8542
  • E-mail: [email protected]
Follow Us

Copyright © Guangxi Dingbo Generator Set Manufacturing Co., Ltd. All Rights Reserved | Sitemap

Update cookies preferences

generator set:

Emergency vs Standby Generator: What’s The Difference? Commercial Generators Trailer Mounted Water Pumps for Sale
Contact Us