The capacity of the diesel generator set decreases. The active substance of the sulfurized battery has become a coarse particle. The diesel generator set cannot be restored to the charged state of lead dioxide and spongy lead. Therefore, the capacity of the diesel generator set is lower than the normal capacity, and its capacity is discharged before the normal battery.


genset maintenance


Low voltage at the end of diesel generator set The internal resistance of sulfurized battery is large, especially the polarization internal resistance, which makes the discharge voltage of diesel generator set low. Low density of electrolyte of diesel generator set Lead sulfate of sulfurized battery cannot be recovered during charging, so the density of electrolyte of diesel generator set will be lower than the normal value.


This phenomenon of diesel generator set can only be observed in the ordinary lead-acid battery of diesel generator set, while the change of electrolyte density cannot be observed in the VRLA battery of diesel generator set.


The contact of the cut-off device in the voltage regulator of the generator set is burned or the parallel coil is short circuited, causing the contact of the generator set to not close; The connection wire from the battery terminal of the generator set voltage regulator to the ammeter is open circuit or has poor contact. After eliminating these two possible faults of the generator set and still not charging, the temporary wire will be connected to the generator set armature and magnetic field terminal.


Due to the contact erosion or weak spring tension of the generator set, the contact of the generator set is poor, and the connection between the two contacts of the generator set is open circuit or the resistance is burnt out; Remove the wires connecting the generator set to the regulator, connect the armature and magnetic field terminal of the generator set with wires, and conduct a fire test with the casing.


If there is a spark, it indicates that the generator set is in good condition, and the reason for not charging may be due to the grounding of the excitation circuit of the generator set regulator; If there is no spark, it indicates that the generator set itself has a malfunction, which may be due to poor contact with the carbon brush or commutator, open circuit in the armature or field coil, or short circuit to ground.


Starlight Power has advanced testing equipment, modern production technology, professional manufacturing technology, perfect quality management system, and strong technical research and development capabilities. It can provide 3KW~2500KW various specifications of ordinary, automatic, four protection, automatic switching, low noise and mobile generator sets, high quality and low energy consumption to meet the diverse power needs of customers, and can also meet users with different voltages and different frequencies. It is required to create a parallel power supply system for multiple units. If you are interested in our product or any question on generator, welcome to send email to [email protected].

Contact Us

  • Add.: No. 10 Kechuang Road, High tech Zone, Nanning, Guangxi, China
  • Tel.: +86 771 5805 269
  • Fax: +86 771 5805 259
  • Cellphone: +86 134 8102 4441
                    +86 138 7819 8542
  • E-mail: [email protected]
Follow Us

Copyright © Guangxi Dingbo Generator Set Manufacturing Co., Ltd. All Rights Reserved | Sitemap

Update cookies preferences

generator set:

Emergency vs Standby Generator: What’s The Difference? Commercial Generators Trailer Mounted Water Pumps for Sale
Contact Us