What should you do if you encounter an abnormality in a silent diesel generator set. The decibel of a silent diesel generator set is very low. What should we do if there is an abnormality during work? The following generator set manufacturers will introduce to you. Silent Diesel The phenomenon of generator current imbalance: the stator three-phase current indications are not equal to each other, the three-phase current difference is large, and the negative sequence current indication value also increases. When the unbalance exceeds the limit and the regular working time is exceeded, the negative sequence signal device sends a "generator asymmetric overload" signal, which constitutes the vibration and heat of the rotor.


quiet diesel generator.jpg


The reason for the current imbalance of the quiet diesel generator set is that one phase of the generator and its circuit is disconnected or the circuit breaker is not in contact with one phase, and a certain transmission line is not working in full phase. The single-phase load of the system is too large: If there is a large-capacity single-phase load, the stator ammeter or meter loop will also cause the stator three-phase ammeter to indicate asymmetrical. The treatment method for the current imbalance of the silent diesel generator set: When the generator three-phase current imbalance exceeds the limit, if it is determined that it is not caused by the meter circuit fault, immediately reduce the load of the diesel generator set to reduce the unbalanced current to the allowable value Following, and then report to the system scheduling. After the three-phase current is balanced, the diesel generator set load is added according to the dispatching instruction.


The difference between the three-phase current of the turbine generator shall not exceed 20% of the rated current, and the current of any one phase shall not exceed its rated value. The negative sequence current promised by the turbine generator shall not be greater than 12% of the rated current. Jiangsu Starlight Power Generation Equipment Co., Ltd. specializes in the production and sales of various generators, generator sets, diesel generators, and diesel generator sets. At the same time, it is a well-known Yuchai diesel generator set partner manufacturer. Adhering to the business philosophy of "cooperation and win-win", we We are always ready to provide you with one-stop service of design, supply, debugging and maintenance. Welcome to consult us for quotation.


Jiangsu Starlight Power Generation Equipment Co., Ltd. was founded in 1974 and is one of the earliest manufacturers of generators and diesel generator sets in China. The company has a registered capital of 218.88 million yuan. The company covers an area of 86,000 square meters and a building area of 55,000 square meters. There are more than 660 employees, including 456 professional technicians and 106 senior technicians. It has 46 sales and service outlets nationwide. The main products are diesel engines, generator sets, and diesel generators, providing users with a one-stop service of design, supply, debugging and maintenance at any time. Starlight has always insisted on using first-class talents, building first-class enterprises, manufacturing first-class products, creating first-class services, and making every effort to build a first-class domestic enterprise. If any question please feel free to visit our website https://www.dieselgeneratortech.com/ or send email to [email protected].

Contact Us

  • Add.: No. 10 Kechuang Road, High tech Zone, Nanning, Guangxi, China
  • Tel.: +86 771 5805 269
  • Fax: +86 771 5805 259
  • Cellphone: +86 134 8102 4441
                    +86 138 7819 8542
  • E-mail: [email protected]
Follow Us

Copyright © Guangxi Dingbo Generator Set Manufacturing Co., Ltd. All Rights Reserved | Sitemap

Update cookies preferences

generator set:

Emergency vs Standby Generator: What’s The Difference? Commercial Generators Trailer Mounted Water Pumps for Sale
Contact Us