Home Products News Contact Us
Home > Supports > Generators > Classification and Models of Generator Sets

Classification and Models of Generator Sets

Apr. 26, 2022

Today we will briefly introduce the classification and models of generator sets.


Classification of generator sets: generator sets can be divided into fixed and mobile types according to their working methods. Generally speaking, generator sets are generally mobile. Generator sets can be generally divided into basic generator sets according to their control functions. It has general control functions and simple protection measures, and mostly adjusts the running state manually, and is generally used as the main power supply or backup power supply. "Three guarantees" type generator set. On the basis of the basic generator set, high water temperature and low oil pressure, automatic overspeed warning and emergency shutdown protection devices are added. Automated generator sets. A self-starting control system is added on the basis of the basic generator set. When the utility power suddenly loses power, the generator set can automatically start, automatically switch, and automatically put into operation. It can automatically stop when the utility power is restored, and has the specified automatic fault protection function. The automatic generator set controlled by a special controller (microcomputer) uses a microcomputer to realize intelligent control, has more complete functions, more reliable operation, and can be unattended.


diesel power generator


Type of generator set: The type of generator set is compiled as follows: variant serial number, use numbers to indicate design serial number, use numbers to indicate control mode, Z is automation. The basic model does not mark the noise level, S is low noise. Ordinary type is not marked. way to move. In Yumu, Q is the automobile power station, T is the trailer power station, and F is the generator set. The type of current, represented by letters, G is the power frequency, and P is the intermediate frequency. Rated power (kW), expressed in numbers eg. 20GF7-8 diesel generator set, indicating the seventh form and the eighth variant of the power frequency (50Hz) diesel generator set with a rated power of 20kW; 50GFSZ1-2 diesel generator set, indicating a power frequency and low noise automatic diesel generator with a rated power of 50kW Generator set, first form, second variant. Single-phase and H-phase generator sets are modeled in the same way, but differ in technical specifications.


Internal combustion generator sets sold on the market, such as Cummins diesel generator sets, Volvo diesel generator sets, Mitsubishi diesel generator sets, Cork diesel generator sets, Shangchai diesel generator sets, Yuchai diesel generator sets, etc., need to be determined according to their respective manuals Unit model and how to use it.


Dingbo Power has advanced testing equipment, modern production technology, professional manufacturing technology, perfect quality management system, and strong technical research and development capabilities. It can provide 3KW~2500KW various specifications of ordinary, automatic, four protection, automatic switching, low noise and mobile generator sets, high quality and low energy consumption to meet the diverse power needs of customers, and can also meet users with different voltages and different frequencies. It is required to create a parallel power supply system for multiple units. If you are interested in our product or any question on generator, welcome to send email to [email protected].

Contact Us

  • Add.: No. 10 Kechuang Road, High tech Zone, Nanning, Guangxi, China
  • Tel.: +86 771 5805 269
  • Fax: +86 771 5805 259
  • Cellphone: +86 134 8102 4441
                    +86 138 7819 8542
  • E-mail: [email protected]
Follow Us

Copyright © Guangxi Dingbo Generator Set Manufacturing Co., Ltd. All Rights Reserved | Sitemap

Update cookies preferences

generator set:

Emergency vs Standby Generator: What’s The Difference? Commercial Generators Trailer Mounted Water Pumps for Sale
Contact Us