Home Products News Contact Us
Home > Supports > Generators > Chongqing Cummins KTAA19-G5 450KW Diesel Generator Set

Chongqing Cummins KTAA19-G5 450KW Diesel Generator Set

Dec. 15, 2023

The Chongqing Cummins KTAA19-G5 450KW diesel generator set adopts a self starting and self stopping model, with a complete set of start stop control devices and related equipment, which has higher durability, reliability, power and fuel economy.


Cummins diesel generator


The main function of a diesel generator set is to provide power to the primary important load within 30 seconds in the event of a power outage or transformer failure in the distribution room, and to put it into rated load operation. When the mains power is restored, it will automatically resume power supply, and the diesel generator set will automatically shut down after cooling delay. The Chongqing Cummins KTAA19-G5 450KW diesel generator set adopts a self starting and self stopping model, with a complete set of start stop control devices and related equipment. Another matching fuel tank with a storage capacity of no more than 1m ³。


Rated power of the unit: 450KW (with main circuit breaker, automatic start stop device, battery, automatic charging device for mains power), complete set of equipment such as oil storage tank, oil supply pipeline, valves, etc. The connecting pipelines of each equipment in the complete set of equipment are included. The unit can meet the demand for parallel operation with later installed units.


Starting method: It can be successfully started three times at room temperature, with a success rate of over 99%. It can quickly self start in case of power outage or emergency, and provide normal power supply within 15 seconds after starting; When the mains power is restored, it can automatically shut down according to the normal shutdown mode; In case of emergency shutdown, the unit can immediately stop automatically.


Power supply: 24V DC battery for startup, equipped with mains float charging function, using maintenance free batteries. The battery can meet the capacity requirement of starting the engine continuously for no less than 6 times without external power supply.


Cooling method: Closed cycle cooling with built-in fan and water tank.


Power factor: 0.8 (lagging)


Controller display type: LCD display, Chinese display.


Display functions: three-phase voltage, three-phase current, frequency, speed, water temperature, oil pressure, battery voltage, oil level, oil volume in indoor and outdoor oil tanks, active power, operating time, number of starts, historical records, time and date.


Alarm and protection functions: high oil pressure, low oil pressure, overspeed, low speed, high voltage, low voltage, high water temperature, high or low battery voltage, overload protection, short circuit protection, grounding protection, generator temperature alarm and protection.


Control methods: panel control start stop, remote control start stop, and computer reading status.


Communication interface type: RS485 communication interface.


Dingbo Power has advanced testing equipment, modern production technology, professional manufacturing technology, perfect quality management system, and strong technical research and development capabilities. It can provide 3KW~2500KW various specifications of ordinary, automatic, four protection, automatic switching, low noise and mobile generator sets, high quality and low energy consumption to meet the diverse power needs of customers, and can also meet users with different voltages and different frequencies. It is required to create a parallel power supply system for multiple units. If you are interested in our product or any question on generator, welcome to send email to [email protected].

Contact Us

  • Add.: No. 10 Kechuang Road, High tech Zone, Nanning, Guangxi, China
  • Tel.: +86 771 5805 269
  • Fax: +86 771 5805 259
  • Cellphone: +86 134 8102 4441
                    +86 138 7819 8542
  • E-mail: [email protected]
Follow Us

Copyright © Guangxi Dingbo Generator Set Manufacturing Co., Ltd. All Rights Reserved | Sitemap

Update cookies preferences

generator set:

Emergency vs Standby Generator: What’s The Difference? Commercial Generators Trailer Mounted Water Pumps for Sale
Contact Us