Home Products News Contact Us
Home > Supports > Generator Sets > What to Prepare for Your 150kVA Generator?

What to Prepare for Your 150kVA Generator?

Nov. 23, 2026

Let's walk through exactly what you need to have ready before delivery day.


Your Pre-Arrival Fluid Checklist

For the 150kVA generator set, please prepare the following fluids before operation:

· Antifreeze/Coolant: 30 Liters

· Engine Oil: 1 barrel (18 Liters)

· Diesel Fuel: 200 Liters (but add only 150 Liters first for initial testing/operation)


Why 150 liters of diesel instead of the full 200? It's simple good practice. Your first run is a test run—you want to verify everything is working smoothly before filling up completely. Once the initial test is done and all systems check out, top up to the full 200 liters.


Winter Specs: This Is Where It Gets Important

Now, here's the part that trips up a lot of new generator owners. When it comes to fluid grades, there's no universal answer—it all depends on your local ambient temperature. Different regions and seasons call for different specifications, and winter is when this matters most.


Let's use a concrete example. If your local temperature drops to -5°C, you should choose an antifreeze rated for -5°C or lower. This ensures your cooling system won't freeze and crack during a cold snap, keeping your generator safe and ready to run.



What to Prepare for Your 150kVA Generator?




The same logic applies to engine oil and diesel fuel. If winter temperatures in your area range between -10°C and +5°C, for instance, -10 diesel is the recommended choice. Using the wrong grade can cause diesel to gel up in the cold, leaving you without power exactly when you need it most. Oil works the same way—colder climates call for lower-viscosity oil that flows properly during startup.


Why Getting This Right Matters

Using incorrect fluid specifications isn't just a minor annoyance—it can cause real damage. The wrong oil might not flow properly in freezing weather, leading to increased wear during startup. Incorrect antifreeze could freeze and expand, potentially cracking your engine block. And the wrong diesel grade can gel up and stall your generator. None of these are problems you want to deal with in the middle of winter.



What to Prepare for Your 150kVA Generator?



What to Do Next

The best approach is simple: consult your local supplier, or tell us your specific location and minimum ambient temperature. With that information, we can provide tailored selection advice for your exact conditions. There's no one-size-fits-all answer here—your generator deserves fluids matched to your environment.


Final Thoughts

Getting your 150kVA generator ready for winter operation doesn't have to be complicated. Have your 30 liters of coolant, 18-liter barrel of engine oil, and 200 liters of diesel ready before delivery day. Then take a moment to confirm the correct specifications for your local climate. A little preparation now means reliable power all winter long.


Got questions about fluid selection for your location? Drop us a message—we're here to help you get it right from day one, email [email protected] or WhatsApp: +8613978689542.

Contact Us

  • Add.: No. 10 Kechuang Road, High tech Zone, Nanning, Guangxi, China
  • Tel.: +86 771 5805 269
  • Fax: +86 771 5805 259
  • Cellphone: +86 134 8102 4441
                    +86 138 7819 8542
  • E-mail: [email protected]
Follow Us

Copyright © Guangxi Dingbo Generator Set Manufacturing Co., Ltd. All Rights Reserved | Sitemap

Update cookies preferences

generator set:

Emergency vs Standby Generator: What’s The Difference? Commercial Generators Trailer Mounted Water Pumps for Sale
Contact Us