When using diesel generator sets for a long time, it is essential to know the functions of the emergency shutdown device and the alarm switch.


diesel engine generator


(1) Emergency Shutdown Device of Diesel Generator Sets

The emergency shutdown device of Shangchai diesel generator sets can be operated electrically, mechanically, or hydraulically. Users should be familiar with the shutdown mode and location of the shutdown device installed on their diesel generator engines, the conditions for activating various shutdown devices, and the reset steps required before restarting.

 

The working principles of all electric shutdown devices are similar. When a certain critical operating condition occurs, a switch is activated to stop the engine. The shutdown device needs to be reset before the engine can be restarted.

 

The shutdown device should be inspected by the company's personnel every 1000 working hours. The engine unit staff can test the hydraulic - mechanical shutdown device every 500 working hours. Generally, the emergency shutdown device should not be used during normal shutdowns. The cause of the sudden shutdown must be identified, and necessary repairs should be carried out.

 

(2) Alarm Switch of Diesel Generator Sets

The set temperature, pressure, or liquid level critical values when the alarm of Shangchai diesel generator sets is activated are more stringent than those for emergency shutdown, that is, the alarm is triggered in advance. The purpose of the alarm is to warn the operator of an impending unsafe situation, and corrective measures must be taken to prevent engine damage.

 

After the alarm is triggered, necessary corrective measures should be taken before the situation turns into an emergency. Each alarm switch is connected by wires to an indicator light, a bell, or a speaker. The alarm continues until the fault is eliminated, and then the indicator light goes out, and the bell or speaker stops ringing. To prevent the alarm from sounding during the repair process, a two - way switch and a red indicator light can be installed. When the switch is toggled to cut off the alarm, the red light lights up. If the switch remains in the "OFF" position after the repair, the red light continues to shine, indicating that the engine is not in a protected state.

 

Guangxi Dingbo Power Equipment Manufacturing Co.,Ltd was founded in 1974 and is one of the earliest manufacturers of generators and diesel generator sets in China. The company has a registered capital of 218.88 million yuan. The company covers an area of 86,000 square meters and a building area of 55,000 square meters. There are more than 660 employees, including 456 professional technicians and 106 senior technicians. It has 46 sales and service outlets nationwide. The main products are diesel engines, generator sets, and diesel generators, providing users with a one-stop service of design, supply, debugging and maintenance at any time. Dingbo has always insisted on using first-class talents, building first-class enterprises, manufacturing first-class products, creating first-class services, and making every effort to build a first-class domestic enterprise. If any question please feel free to visit our website https://www.dieselgeneratortech.com/ or send email to [email protected].

Contact Us

  • Add.: No. 10 Kechuang Road, High tech Zone, Nanning, Guangxi, China
  • Tel.: +86 771 5805 269
  • Fax: +86 771 5805 259
  • Cellphone: +86 134 8102 4441
                    +86 138 7819 8542
  • E-mail: [email protected]
Follow Us

Copyright © Guangxi Dingbo Generator Set Manufacturing Co., Ltd. All Rights Reserved | Sitemap

Update cookies preferences

generator set:

Emergency vs Standby Generator: What’s The Difference? Commercial Generators Trailer Mounted Water Pumps for Sale
Contact Us