Diesel generator sets need to be maintained. The normal operation of diesel generator sets has a great relationship with the correct maintenance and maintenance of diesel generator sets. The first is the cooling system. If the cooling system is faulty, it will As a result, the cooling effect is not good and the water temperature in the unit is too high and the unit shuts down; the water tank leaks and the water level in the water tank drops, and the diesel generator set cannot operate normally. If the increase in the amount of coke deposits causes the fuel injection volume of the fuel injector to be affected to a certain extent, the fuel injection nozzle is not burned sufficiently, the fuel injection volume of each cylinder of the engine will be uneven, and the operating conditions will be unstable.


generator maintenance.jpg


If the battery is not maintained for a long time, the electrolyte moisture will not be compensated in time after evaporation, and the battery charger is not equipped to start the battery, and the battery power will be reduced after a long-term natural discharge. Of course, the engine oil has a certain persistence period, that is to say, if it is not used for a long time, the physical and chemical functions of the engine oil will change, and the cleanliness of the diesel generator set will deteriorate during operation, which will cause damage to the parts. Water entering the air of the diesel generator set will condense when the temperature changes, forming water droplets and hanging on the inner wall of the fuel tank. When the water droplets flow into the diesel, the water content of the diesel will exceed the standard. When such diesel enters After the high-pressure oil pump of the engine, the precision coupling parts will be corroded. If it is serious, the diesel generator set will be damaged.


During the operation of the diesel generator set, oil stains or impurities will deposit on the wall of the filter screen, and the filtering function of the filter will be reduced if the filter is too much deposited, the oil path will not be dredged, and the equipment will be unable to supply oil when the equipment is working. malfunction. Due to the chemical properties of lubricating oil or oil ester and the iron filings that occur after mechanical wear, these not only reduce its lubricating effect, but also damage other parts. At the same time, because lubricating oil has a certain corrosive effect on rubber seals, other oil seals It also deteriorates due to its aging at any time. If the diesel generator set has been used for too long, the line joints may become loose, and regular inspections are required.


Starlight Power has advanced testing equipment, modern production technology, professional manufacturing technology, perfect quality management system, and strong technical research and development capabilities. It can provide 3KW~2500KW various specifications of ordinary, automatic, four protection, automatic switching, low noise and mobile generator sets, high quality and low energy consumption to meet the diverse power needs of customers, and can also meet users with different voltages and different frequencies. It is required to create a parallel power supply system for multiple units. If you are interested in our product or any question on generator, welcome to send email to [email protected].

Contact Us

  • Add.: No. 10 Kechuang Road, High tech Zone, Nanning, Guangxi, China
  • Tel.: +86 771 5805 269
  • Fax: +86 771 5805 259
  • Cellphone: +86 134 8102 4441
                    +86 138 7819 8542
  • E-mail: [email protected]
Follow Us

Copyright © Guangxi Dingbo Generator Set Manufacturing Co., Ltd. All Rights Reserved | Sitemap

Update cookies preferences

generator set:

Emergency vs Standby Generator: What’s The Difference? Commercial Generators Trailer Mounted Water Pumps for Sale
Contact Us