Home Products News Contact Us
Home > Supports > Generator Sets > The Diesel Generator Set Needs A Minor Repair After Every 500h Of Operation

The Diesel Generator Set Needs A Minor Repair After Every 500h Of Operation

Jan. 10, 2023

1、 Minor repair of internal combustion engine.

The minor repair of internal combustion engine is irregular maintenance repair. It is mainly to eliminate the common faults in the process of use in time to keep the internal combustion engine in good condition at any time. Its scope of operation is regular maintenance, eliminating the damage of parts (contact ablation, etc.) caused by natural wear, and replacing and adjusting some defective parts, assemblies, assemblies and assemblies caused by improper use and maintenance. Its basic content is to dredge the oil, water and exhaust channels. Eliminate oil, water and gas leakage. Remove the carbon and oil deposits on the cylinder head, piston and piston ring, and replace the piston ring. Adjust the tightness of fan belt, valve clearance, oil pressure, injection pressure and fuel supply time. Change the oil and clean the oil sump, air filter, diesel and oil filter. Repair the starting motor and charging diesel generator. Replace some parts damaged due to unexpected accidents.

 

diesel generator set


2、 Minor repair of diesel generator.

The minor repair of diesel generator is carried out after every season or after 500 hours of accumulated work. In addition to completing the daily maintenance of diesel generator, its main contents are as follows.

 

① Open the window cover, and if dust is found in the motor, clean it. Use dry and clean compressed air to blow the dust in all parts of the motor, and note that the pressure should not exceed 2x105Pa. The surface of each winding and the inside of the fan shall also be thoroughly cleaned to maintain effective ventilation and heat dissipation.

 

② Clean the collector ring or commutator surface, brush and brush holder, etc., wipe with a soft dry cloth dipped with a little gasoline (alcohol kerosene, etc.), then dry the surface with other clean cloth, and check the wear of the brush and its contact with the collector (or commutator), repair or adjust if necessary, and check the pressure of the brush at the same time. If not, adjust it.

 

③ Remove the small end cover of the motor bearing (one at the shaft extension end need not be taken down), check the consumption and cleanliness of the lubricating oil, add it properly if the oil is found to be insufficient, and clean and replace the lubricating oil if the color is uneven, hardened or contains other metal impurities. When disassembling the motor, master the essentials to avoid damaging the motor.

 

④ Carefully check the electrical and mechanical connections at all places, and clean and firmly connect them if necessary.

 

A minor repair of diesel generator set can find some small problems in time, avoid turning small problems into big problems, and can well extend the service life of diesel generator set.

 

Jiangsu Starlight Electricity Equipments Co.,Ltd. is a manufacturer of professional generators, diesel generator sets, Cummins generator sets, Volvo generator sets, etc. The company has advanced testing equipment, excellent production technology, professional manufacturing technology, perfect quality management system, and Strong R&D technical strength. It can provide 15KW-2500KW various specifications of universal, automatic, four protection, automatic switching, low noise and mobile, etc., high-quality, low-energy generating sets to meet customer power needs, and can also meet users' different voltages and different frequencies, as well as the power supply system of multiple units connected in parallel, welcome customers to inquire. For more details, please contact us with [email protected].


Contact Us

  • Add.: No. 10 Kechuang Road, High tech Zone, Nanning, Guangxi, China
  • Tel.: +86 771 5805 269
  • Fax: +86 771 5805 259
  • Cellphone: +86 134 8102 4441
                    +86 138 7819 8542
  • E-mail: [email protected]
Follow Us

Copyright © Guangxi Dingbo Generator Set Manufacturing Co., Ltd. All Rights Reserved | Sitemap

Update cookies preferences

generator set:

Emergency vs Standby Generator: What’s The Difference? Commercial Generators Trailer Mounted Water Pumps for Sale
Contact Us