Shanghai Yangfa Power Co., Ltd., a Sino US joint venture, was established in 2007 and is located in the Baoshan Urban Industrial Park in Shanghai. It is a professional engine manufacturing enterprise that integrates design, R&D, production, and sales, with strong technical strength and advanced production equipment.


genset generator


The diesel engine of the 365kw Weiman diesel generator set in the Dingbo series is produced by Shanghai Yangfa Power Co., Ltd., with the model number DE15A500. The product introduces and absorbs advanced design, production, and management concepts from European and American engines, adopts a V-shaped arrangement, low compression ratio, and focuses on collective structural strengthening. The relevant parameters of the 365kw Weiman diesel generator set DE15A500 are as follows:


Genset Model

DB-365GF

Genset Output Power (KW/KVA)

330/450

Standby Power(KW/KVA)

365/496

Brand and Model

WeimanDE15A500

Manufacturer

Shanghai Yangfa Power Co., Ltd

Cylinder Diameter x Stroke (mm)

128×142mm

Cylinders Number

818/1113

Oil Capacity(L)

25

Speed Control

electronic speed control

Rated Frequency

50Hz

Rated Speed

1500rpm

Output Current

540A

Output Voltage

400V/230V

Start Mode

DC24V Electric Start

Cooling Method

Closed Water Circulation Cooling

Fuel Consumptiong/kw.h

≤195

Emission

China Stage III

External Dimensions
L×W×H(mm)

1481×1389×1288

Generator Set Weight(kg)

1050

As a professional diesel generator manufacturer, we always insist on using first-class talents to build a first-class enterprise, create first-class products, create first-class services, and strive to build a first-class domestic enterprise. If you would like to get more information welcome to contact us via [email protected].

Contact Us

  • Add.: No. 10 Kechuang Road, High tech Zone, Nanning, Guangxi, China
  • Tel.: +86 771 5805 269
  • Fax: +86 771 5805 259
  • Cellphone: +86 134 8102 4441
                    +86 138 7819 8542
  • E-mail: [email protected]
Follow Us

Copyright © Guangxi Dingbo Generator Set Manufacturing Co., Ltd. All Rights Reserved | Sitemap

Update cookies preferences

generator set:

Emergency vs Standby Generator: What’s The Difference? Commercial Generators Trailer Mounted Water Pumps for Sale
Contact Us