The rated speed of our Cummins diesel generator is 1500 rpm. For the generator set to maintain a stable speed, a governor is required. The governor can automatically adjust the fuel supply according to the load changes of the diesel generator set. It can be said to be an essential factor for the stability of the Yuchai diesel generator.


Cummins diesel generator


Now, let's specifically talk about the two main uses of the governor:

 

1. When the speed of the Cummins diesel generator deviates from the set value, the governor can promptly make corresponding reaction actions. It also has the function of a restoring force to return the governor to its initial state. You should know that the spring in the centrifugal governor of our diesel engine parts is the part that generates the restoring force. Such a governor is also called a statically stable governor. However, a statically stable governor may also experience dynamic instability during the adjustment process. When the adjustment action is excessive and reverse adjustment occurs, in fact, the adjustment action will form an oscillation process. A governor that can quickly reduce the oscillation is called a dynamically stable governor. Otherwise, it is a dynamically unstable governor, and the latter cannot fully guarantee the normal operation of the diesel generator set.

 

 

2. Adding damping to the diesel generator set's adjustment system is also a commonly used method to improve dynamic stability. The damping in the adjustment system, such as the friction in the kinematic pair, makes the governor have a certain degree of insensitivity. In other words, when the speed of the controlled shaft slightly deviates from the set value, the governor will not produce a corresponding action. The insensitivity of a mechanical governor is generally about 1% of its set value. On the contrary, a governor with excessively high sensitivity will also produce unnecessary adjustment actions due to the periodic speed fluctuations during the normal operation of the diesel generator.

 

Guangxi Dingbo Power Equipment Manufacturing Co.,Ltd was founded in 1974 and is one of the earliest manufacturers of generators and diesel generator sets in China. The company has a registered capital of 218.88 million yuan. The company covers an area of 86,000 square meters and a building area of 55,000 square meters. There are more than 660 employees, including 456 professional technicians and 106 senior technicians. It has 46 sales and service outlets nationwide. The main products are diesel engines, generator sets, and diesel generators, providing users with a one-stop service of design, supply, debugging and maintenance at any time. Dingbo has always insisted on using first-class talents, building first-class enterprises, manufacturing first-class products, creating first-class services, and making every effort to build a first-class domestic enterprise. If any question please feel free to visit our website https://www.dieselgeneratortech.com/ or send email to [email protected].

Contact Us

  • Add.: No. 10 Kechuang Road, High tech Zone, Nanning, Guangxi, China
  • Tel.: +86 771 5805 269
  • Fax: +86 771 5805 259
  • Cellphone: +86 134 8102 4441
                    +86 138 7819 8542
  • E-mail: [email protected]
Follow Us

Copyright © Guangxi Dingbo Generator Set Manufacturing Co., Ltd. All Rights Reserved | Sitemap

Update cookies preferences

generator set:

Emergency vs Standby Generator: What’s The Difference? Commercial Generators Trailer Mounted Water Pumps for Sale
Contact Us