Home Products News Contact Us
Home > Supports > Generator Sets > Purchase Of Diesel Generator Sets Cannot Be Compromised On Power

Purchase Of Diesel Generator Sets Cannot Be Compromised On Power

Mar. 28, 2023

When enterprises purchase diesel generator sets, they want to purchase products with high cost performance. Some enterprises may compromise at certain nodes in order to reduce their budgets. For example, brand, model, or status may save a portion of the budget, but Jiangsu Starlight Electricity Equipments Co.,Ltd. reminds you that when purchasing a diesel generator set, you must not compromise on power or quality to save money, as this is the basis for the efficiency and service life of the diesel generator set.

 

Generally, the cost of a diesel generator set depends on the following aspects:

1. Manufacturer of the generator set.

2. Generator set model.

3. Generator set power.

4. Generator brand and quality.

5. Generator set status: brand new/second-hand/renovated.

 

If you want to save budget, you can make appropriate adjustments in brand, model, and status, but the power of the unit must be selected within the appropriate range. It is recommended to calculate the maximum power requirements of all devices on which the enterprise is highly dependent, know the power required to start these devices, and also consider the increase in power load caused by additional machines. Knowing the approximate power, you can choose the best power diesel generator set. The specific calculation method is as follows:

 

diesel generator set


1. If the maximum user load exceeds 8 hours of operation per day, the common power of the selected unit should be 1.25 times the maximum load.

 

2. If the maximum load of the user is 4-8 hours per day, the common power of the selected unit should be 1.2 times the maximum load.

 

3. If the maximum load of the user is 2-4 hours per day, the common power of the selected unit should be 1.15 times the maximum load.

 

4. If the maximum load of the user is 1-2 hours per day, the common power of the selected unit should be 1.1 times the maximum load.

 

5. If the maximum user load is less than 1 hour per day, the common power of the selected unit is equal to the maximum load.

 

To ensure that users can purchase the required power, Jiangsu Starlight Electricity Equipments Co.,Ltd. reminds you to also note that the generator power can be divided into KVA and KW. KVA is apparent power, and KW is effective power. The relationship between them is 1KVA=0.8KW. Imported units generally use KVA as the power unit, while domestic electrical equipment generally uses KW as the unit, so attention should be paid to the unit when calculating power. If it is KVA, it should be converted into KW according to the formula.


Founded in 1974, Jiangsu Starlight Electricity Equipments Co.,Ltd., a wholly-owned subsidiary of Jiangsu Starlight Power Group, is one of the earliest manufacturers of generating sets in China. Over the past 40 years, the company has won the recognition of users by relying on advanced testing equipment, modern production technology, professional manufacturing technology, perfect quality management system, strong R&D technology strength. For more details, please contact us with [email protected].


Contact Us

  • Add.: No. 10 Kechuang Road, High tech Zone, Nanning, Guangxi, China
  • Tel.: +86 771 5805 269
  • Fax: +86 771 5805 259
  • Cellphone: +86 134 8102 4441
                    +86 138 7819 8542
  • E-mail: [email protected]
Follow Us

Copyright © Guangxi Dingbo Generator Set Manufacturing Co., Ltd. All Rights Reserved | Sitemap

Update cookies preferences

generator set:

Emergency vs Standby Generator: What’s The Difference? Commercial Generators Trailer Mounted Water Pumps for Sale
Contact Us